Use and Care Manual
13
ROTATE THE TABLE
1. Loosen the table locking handle and turn the table around the col-
umn to the desired position.
NOTE: The rack should rotate around the column with the table sup-
port bracket. If the rack binds and does not rotate, slightly loosen the
set screw in the rack collar.
2. Tighten the table lock handle before drilling.
TILT THE TABLE
1. Loosen the bevel lock bolt (Fig. M - 1) with a 19mm socket or
wrench.
2. Tilt the table to the desired angle, using the bevel scale (Fig. N) as a
basic guide.
3. Re-tighten the bevel lock bolt.
4. To return the table to its original horizontal position, loosen the
bevel lock bolt.
ASSEMBLY AND ADJUSTMENTS
Fig. M
Fig. N
Fig. O
5. Realign the table to the 0° setting on the bevel scale.
6. Tighten the bevel lock bolt with the wrench.
WARNING: To avoid injury, make sure the chuck key is removed from the chuck before starting any
drilling operation.
INSTALLING A DRILL BIT
1. Place the chuck key into the side keyhole of the chuck, meshing the
key with the gear teeth.
2. Turn the chuck key counterclockwise to open the chuck jaws.
3. Insert a drill bit into the chuck so the chuck jaws grip as much of the
bit’s shank as possible.
4. Center the drill bit in the chuck jaws before the final tightening of the chuck.
5. Tighten the chuck jaws using the chuck key to ensure that the drill bit will not slip while drilling. Tighten the
jaws using all three keyholes of the chuck.
6. Remove the chuck key. Store in the rubber key holder, mounted above the feed hub.
1