GENERATOR COMPONENTS
Please familiarize yourself with the locations and functions of the various components and controls
of your generator.
16
17
(1) Choke Lever- Adjusts the amount of air let
into the engine.
(2) Air Cleaner- A removable, cleanable,
sponge-like element that limits the amount of
dirt pulled into the engine.
(3) Fuel Valve- Allows fuel to enter engine.
(4) Fuel Filter Cup- Traps dirt and water from
fuel before it enters the engine.
(5) Recoil Starter- Pull-cord for starting engine.
(6) Electric start Switch- To start/stop engine.
(7) Oil Fill and Dipstick- Location for checking
and filling engine oil.
(8) Circuit Reset Buttons- Reset buttons that
protect the generator from electrical overload.
(9) Ground Terminal- Connect grounding wires
here to properly ground unit.
(10) 120 Volt AC Duplex Receptacle - To connect
electrical devices that run 120 Volt, 60 Hz, single
phase, AC current, rated 20 amps
(11) 120/240 Volt AC Receptacle- To connect
electrical devices that run 120 and/or 240 Volt,
60 Hz, single phase, AC current, twist lock
receptacle, rated 30 amps.
(12) Muffler with Spark Arrester- Reduces engine
noise.
(13) Spark Plug- Provides proper engine ignition.
(14) Fuel Cap- Access to the fuel tank for adding fuel
(15) Fuel Gauge- Indicates the amount of fuel in the
tank.
(16) Wheel
(17) Handle-hold up the handle, and pull it to walk