Owner`s manual

20
6. PLACE PROPANE [LPG] CYLINDER [EITHER 20LB. 40LB. OR 100LB.] WITHIN APPROX. 8’ OF THE
GENERATOR. ATTACH THE LARGE “BLACK” END OF THE GAS SUPPLY
HOSE TO THE DESIRED SIZE PROPANE CYLINDER. THIS IS A STANDARD
“RIGHTY-TIGHTY” THREAD PATTERN. HAND TIGHTEN ONLY. THE OPPOSITE
END OF THE GAS SUPPLY HOSE SHOULD ALREADY BE ATTACHED TO THE LARGE
REGULATOR LOCATED AT THE LOWER REAR CORNER OF THE GENERATOR.
IF NOT. USE TEFLON TAPE INCLUDED,AND TIGHTEN USING A 19MM OPEN END
WRENCH.
7. OPEN VALVE ON PROPANE TANK. OPEN LARGE VALVE ON SUPPLY HOSE LINE. LOCATE SMALL
“INLINE” VALVE NEXT TO LARGE VALVE JUST OPENED. TURN THIS VALVE APPROX.THREE TURNS
COUNTER CLOCKWISE. GAS SUPPLY HOSE IS NOW OPERATIONAL .
8.LOCATE ON THE RED BOTTON ON THE PRESSURE RELEASE VALVE, AND PUSH IT DOWN FOR 2
TO 3 SECONDS THEN RELEASE.
9.IF BELOW 70 DEGREES/F PULL OUT CHOKE ROD TO THE “ON” POSITION
10. TURN IGNITION KEY CLOCKWISE TO ENGAGE ELECTRIC STARTER.
IMMEDIATELY AFTER ENGINE STARTS RELEASE KEY AND BEGIN TO SLOWLY PUSH IN CHOKE ROD.
AFTER STARTING THE CHOKE ROD SHOULD BE FULLY RETURNED TO THE “OFF” POSITION WITHIN
5-30 SECONDS DEPENDING UPON THE OUTSIDE
AMBIENT TEMPERATURE. ENGINE SHOULD NOW BE RUNNING SMOOTHLY. NO FURTHER
ADJUSTMENTS ARE NECESSARY. IF ENGINE DID NOT START, PLEASE
REFER TO TROUBLE SHOOTING GUIDE IN OWNERS MANUAL.
11. AFTER ENGINE HAS BEEN RUNNING FOR APPRO XIMATELY 2 MINUTES YOU ARE
NOW READY TO BEGIN DRAWING ELECTRICITY. RETURN TO THE VOLTAGE SELECTION SWITCH.
TURN SWITCH FROM THE PREVIOUSLY SET “0”/OFF POSITION TO EITHER THE 120 VOLT OR 240
VOLT POSITION. CHECK VOLTAGE OUTPUT GUAGE. BE SURE YOU HAVE SET T O YOUR REQUIRED
VOLTAGE LEVEL.
PAGE 3
YOUR GENERATOR IS NOW FUNCTIONING AND FULLY OPERATIONAL.
YOU MAY BEGIN USE…
12. TO SHUT OFF THE MACHINE SIMPLY TURN THE KEY TO THE OFF POSITION.
IMMEDIATELY CLOSE THE SMALL “INLINE” VALVE . CLOSE THE PROPANE
TANK VALVE. CLOSE THE LARGE GAS LINE SUPPLY HOSE VALVE. TURN VOLTAGE SELECTOR
SWITCH TO “0” OR OFF POSITION. DISCONNECT GAS SUPPLY LINE.
*****DO NOT UNDER ANY CONDITIONS ATTEMPT TO OPERATE THIS GENERATOR
POWERED BY EITHER GASOLINE OR PROPANE INDOORS. THE EXHAUST GASES
OF THIS GENERATOR CANNOT BE MADE NON TOXIC…. PROLONGED BREATHING
OF THESE FUMES WILL RESULT IN DEATH. THIS GENERATOR MUST BE
OPERATED OUT OF DOORS ONLY IN WELL VENTILATED LOCATIONS.