Owner`s manual

17
To start the generator with liquid propane gas:
1. Switch the fuel valve to OFF position, check that there is no loa d in any receptacle.
2. Connect the hose with the regulator (see Picture 18)
3. Connect the regulator to the liquid propane gas supply and then turn on the liquid propane gas
supply, make sure there is no leakage.
4. When start the engine, Put the choke to half ope n if the generator is warm(viz. the generator was
used just before) and pull it to open after the engine starts; put the choke to open if the generator is
cold (viz. the generator have not been used for more than half an hour). (See Picture 16)
5. Locate on the red botton on the pressure release valve, and presse for 2 to 3 seconds and release.
( See Picture 19)
6. Connect electrical loads to generator after it runs smoothly.
7. Before stopping, unload all electrical devices.
8. Disconnect the LPG supply.
9. Turn the start key to OFF position.
WARNING: WHEN USING MP5500DF
MAKE SURE ALL THERE IS NO SPARK AROUND THE GENERATOR.
1. Before using, make sure all the connectors and hose are well sealed.
2. Connect electrical devices to generator ONLY after the generator runs smoothl y.(For there may be
remained gasoline in the carburetor, the generator may performance not steady enough at the
beginning.
3. If liquid propane gas leakage happens, shut off the LPG supply first and then unload electrical
devices promptly.
4. When stopping the e ngine, unload all the devices and turn off the LPG SWITCH on the panel
firstly, after the engine is silent, turn the KEY to OFF position, shut off the LPG supply lastly.
5. Keep the pressure in LPG tank higher than 85PSI, or the generator will not output f ull power.
Figure 14- Fuel Valve in the “OFF” position
Figure 15- Start with LPG( Liquid Propane Gas)
Figure 16- Pull choke out for closed position.
Push in for open position.