Specifications
SERVICING INSTRUCTIONS (continued)
SERVICE
CABINET COMPONENTS
A. TANK SHELF
1. Removal
a. Remove two screws (g).
b. Lift the front of the tank shelf until the rear lip clears the front
assembly.
c. Lift the tank shelf off.
2. Installation
a. Hold tank shelf vertically. Slide rear lip under front assembly.
b. Rotate tank shelf to the horizontal position. The left and right
lips go on the outside of the wrap. The flange with the
weldnuts (g) goes behind the front web of the wrap.
c. Insert and tighten two screws (g).
B. SUPPORT COVER
1. Removal
a. Remove two screws (a) from top cover, and two screws (b)
from front assembly.
b. Lift support cover straight up to remove.
2. Installation
a. Lower support cover into position. The left and right lips of the
front assembly go on the outside of the support cover. The
front lip of the support cover hooks over the outside of the front
assembly.
b. Install and tighten two screws (a) into the top cover, and two
screws through the lips of the front assembly into the support
cover.
C. FRONT ASSEMBLY
1. Removal
a. Remove the support cover (See B. above).
b. Remove four screws (c) from the front of the front assembly.
c. Disconnect the electrical connector for the front assembly.
Disconnect the three indicator LED connectors from the control
board (see drawing at right). Disconnect the nozzle supply hose
from the inductive heater by gently working the hose off of the
barbed fitting.
d. The front assembly may now be removed.
2. Installation
a. Reconnect the nozzle supply hose by gently working the hose
onto the inductive heater barbed fitting, making sure it is fully
seated. Reconnect the electrical connector for the front assy.
It is keyed and will only connect one direction. Reconnect the
three indicator LED connectors to the power board. Observe
the locating tab to ensure proper connection.
b. Set the front assembly in position and reinstall four screws (c).
c. Reinstall support cover and tank shelf as detailed above.
WARNING
Electric Shock
Hazard
Disconnect Water-Max™
from electrical power
before removing any panel or
cover.
IMPORTANT
Shut off water supply
before performing any service
to Water-Max™
TOOLS REQUIRED:
#2 Phillips Screwdriver
Container to hold
fasteners
27