001 WELLS MANUFACTURING 10 Sunnen Dr., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www.wellsbloomfield.
LIMITED WARRANTY STATEMENT prices charged by Wells Manufacturing for its products are based upon the limitations in this warranty. Seller’s obligation under this warranty is limited to the repair of defects without charge by a Wells Manufacturing factory authorized service agency or one of its sub-service agencies. This service will be provided on customer’s premises for non-portable models.
TABLE OF CONTENTS WARRANTY FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY LISTING INFORMATION INSTALLATION OPERATION CLEANING INSTRUCTIONS TROUBLESHOOTING SUGGESTIONS MAINTENANCE INSTRUCTIONS EXPLODED VIEW & PARTS LIST WIRING DIAGRAM PARTS & SERVICE CUSTOMER SERVICE DATA xi 2 3 3 4 5 6 8 9 10 18 20 21 INTRODUCTION Thank You for purchasing this Wells Manufacturing appliance.
FEATURES & OPERATING CONTROLS INDICATOR LIGHT TEMPERATURE CONTROL KNOB IL2462 A. THERMOSTAT 1. On thermostatically controlled warmers, power is applied to the heating element according to the control knob position and the actual temperature at the temperature sensing thermobulb. 2. The desired temperature is controlled by rotating the temperature control knob. The knob has a numeric scale, where higher numbers correspond to higher temperature. 3.
PRECAUTIONS AND GENERAL INFORMATION This appliance is intended for use in commercial establishments only. This appliance is intended to hold pre-heated food for human consumption. No other use is recommended or authorized by the manufacturer or its agents. Operators of this appliance must be familiar with the appliance use, limitations and associated restrictions. Operating instructions must be read and understood by all persons using or installing this appliance.
INSTALLATION WARNING: RISK OF INJURY Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical and plumbing codes. Failure can result in personal injury and property damage. CAUTION FIRE HAZARD Avoid storing flammable or combustible materials in, on or near the appliance. CAUTION SHOCK HAZARD The ground prong of the electrical cord is part of a system designed to protect you from electrical shock. In the event of internal damage to the warmer.
OPERATION WET OR DRY OPERATION for WARMERS 1. Carefully read the description of the warmer operation on the specification sheet. 2. a. Most warmers are designed for WET OR DRY operation. b. Warmers may be used wet, or may be used dry. However warmers may NOT be used wet-to-dry or dry-to-wet unless they have been allowed to cool to room temperature between the change in wet or dry operation. c. Wells Manufacturing recommends operating WET for consistent food heating. d.
CLEANING INSTRUCTIONS SHOCK HAZARD Do NOT splash or pour water into or over any control panel or wiring. CAUTION: SHOCK HAZARD Disconnect warmer from electric power before cleaning CAUTION: BURN HAZARD Allow warmer to cool completely before cleaning. CAUTION: SHOCK HAZARD DO NOT submerge warmer in water. DAILY CLEANING INSTRUCTIONS PREPARATIONS: Turn control knob(s) to OFF. Unplug the warmer. Allow warmer to cool before proceeding.
CLEANING INSTRUCTIONS (continued) CAUTION: WEEKLY CLEANING INSTRUCTIONS PREPARATIONS: Remove any insets, pans and/or adapter tops. Drain or remove water from well if used for wet operation. FREQUENCY: Weekly, or whenever lime or scale is seen accumulating on the sides of the warmer pans. TOOLS: Commercial Delime Cleaner Plastic Scouring Pad Clean Cloth or Sponge 1. Add water to pans until water is at normal operating level (1” - 1 1/2” deep) or covers accumulated scale. 2.
TROUBLESHOOTING SUGGESTIONS SYMPTOM No power to warmer Warmer will not heat Warmer trips circuit breaker Warmer slow to heat POSSIBLE CAUSE SUGGESTED REMEDY Circuit breaker off or tripped Reset circuit breaker Unit not plugged in Make sure unit is plugged in to power receptacle Temperature control not set Set control to desired temperature Internal damage Contact you Authorized Wells Service Agency for repairs Pan leaking or other internal damage Contact your Authorized Wells Service Agency
MAINTENANCE INSTRUCTIONS CARE OF STAINLESS STEEL Stainless steel is a marvelous material: strong, lustrous and low maintenance. With a minimum of care, it will normally retain its beauty and durability for the life of the equipment. In some applications, however, special care is required in order to maintain stainless steel’s special properties. External components, such as cabinets and control panels, are finished with a grain pattern.
EXPLODED VIEW: SMPT MODEL SMPT 1 17 16 15 14 13 2 12 18 4 5 11 10 9 8 MODEL: SMPT 7 IL1927, Rev.
PARTS LIST: SMPT MODEL: SMPT FABRICATED WARMER Item No 1 Description Application 2P-38628 PLUG HOLE 5/8 DIA D8-WL0339 ASSY, CORDSET 120V, 15A 14G D8-WL0340 ASSY, CORDSET 6-15P 16/3W 4FT D8-WL0342 ASM-CORD SET CEE7/VII 3 2K-31217 STRAIN RELIEF 90DEG 4 D8-303352 BRKT THERMO BULB D8-WL0051 BASE, STD REAR WIRED CORD D8-307895 BAE BTM WIRED CORD D8-Z15106 BOTTOM SMPTD (DRAIN) 7 2A-33572 FEET ADJ 2IN 8 2R-Y5092 BLK PLASTIC LEG, 4 INCH 9 2R-40498 KNOB ASSY 10 D8-30256 TRIM RING AS
EXPLODED VIEW: SMPT-27 MODEL SMPT-27 15 1 2 14 13 12 3 16 11 4 10 9 5 6 8 7 MODEL: SMPT-27 SOME ITEMS ARE INCLUDED FOR ILLUSTRATION PURPOSES AND MAY VARY SLIGHTLY FROM ACTUAL APPEARANCE. IL1928, Rev.
PARTS LIST: SMPT-27 MODEL: SMPT27, SMPTD27 FABRICATED WARMER Item No 1 2 3 4 Description INSUL SIDE BMW-327 427 2H-307893 INSULATION FRONT Application D8-WL0339 ASSY, CORDSET 120V, 15A 14G 120V D8-WL0340 ASSY, CORDSET 6-15P 16/3W 4FT 208/240V 2K-31217 STRAIN RELIEF 90DEG 67-301929 PAN ELEMENT ONLY SMPT-27 WS-503840 KIT ELEM PAN W/ELEMENT SMPT-27 D8-Z16231 PAN, ELEMENT SMPTD-27 SMPTD-27 D8-WL0329 PAN ELEM ASSY SMPTD27-120 SMPTD27-120 D8-WL0328 PAN ELEM ASSY SMPTD27 SMPTD27-208/240
EXPLODED VIEW: SW10T MODEL SW10T 1 2 3 4 5 6 7 8 9 10 11 12 7 14 7 15 SK2674, Rev -, 7/31/13 Model: SW10T, Countertop Warmers 14 001 p/n 2M-303305 Owners Manual CT Warmers / Thermostat Control 13
PARTS LIST: SW10T Model: SW10T Countertop Warmer Fig No Part No.
EXPLODED VIEW: TMPT MODEL TMPT 14 13 16 1 15 12 11 2 3 9 8 4 7 5 6 MODEL: TMPT IL1930, Rev.
PARTS LIST: TMPT MODEL: TMPT FABRICATED WARMER Item No 1 2 3 4 5 Part No Description Application 2H-307893 INSULATION FRONT 2H-46073 INSUL SIDE 2K-31217 STRAIN RELIEF 90DEG mfg. before 11/2011 2K-Y3240 BUSHING ST 17-2 mfg.
EXPLODED VIEW: HMPGW 1 2 3 4 6 5 7 8 11 17 12 13 16 14 15 18 21 19 20 SK2683 MODEL: HMPGW, Fabricated Warmer 16 REV.
PARTS LIST: HMPGW Model: HMPGW, Fabricated Warmer Fig No.
001 p/n 2M-303305 Owners Manual CT Warmers / Thermostat Control WIRING DIAGRAM 18
001 p/n 2M-303305 Owners Manual CT Warmers / Thermostat Control WIRING DIAGRAM 19
001 p/n 2M-303305 Owners Manual CT Warmers / Thermostat Control NOTES
001 p/n 2M-303305 Owners Manual CT Warmers / Thermostat Control NOTES
PARTS & SERVICE DO NOT place food directly into the warmer pan. DESCRIPTION PART NO. ADAPTERS & INSETS ADAPTER TOP, convert SMPT, HW/SMP or 1 side of TMPT to hold three 4 qt. insets WS-21615 ADAPTER TOP, convert SMPT, HW/SMP or 1 side of TMPT to hold one 7 qt. and one 4 qt. inset DD-21617 ADAPTER TOP, convert SMPT, HW/SMP or 1 side of TMPT to hold one 11 qt. and one 7 qt. inset WS-21621 ADAPTER TOP, convert SW-10T from 11 qt. inset to 4 qt.
PARTS & SERVICE (continued) DESCRIPTION PART NO. ACCESSORIES IMPORTANT: Use only factory authorized service parts and replacement filters. 8 oz.
WELLS MANUFACTURING 10 Sunnen Dr., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www.wellsbloomfield.