Specifications
INSTALLATION
5
5. For “top-mounted” warmers (i.e. warmers mounted from above the
counter top):
a.
Verify that provided sealants are applied to the underside
of the warmer top ange prior to setting the unit into the cutout.
b. After installation, verify that the tabs on the Wellsloks are
turned out to lock the warmer into the counter
c.
Apply a thin bead of food-grade silicone sealant around the
ange to seal it to the counter.
d.
Wellslok extension kits are available for installing warmers
in counter tops where the standard Wellslok would not
normally reach. The extension kit will adapt to counter
tops up to 1¾” thick.
ELECTRICAL INSTALLATION
1. Refer to the product nameplate. Verify the electrical service power.
Voltage and phase must match the nameplate specications.
Wiring the warmer to the wrong voltage can severely damage the
unit or cause noticeably decreased performance.
2. Available electrical service amperage must meet or exceed the
specications listed on the specication sheet provided with the
warmer.
3.
Warmer and control unit must be connected to an appropriate
building ground. Ground connection will be marked “GND” or
” “ .
NOTE: Wire gauge, insulation type and temperature rating , as
well as type, size and construction of conduit, must meet or exceed
applicable specications of local codes and of the National
Electrical Code.
E.
PLUMBING INSTALLATION
For use in the State of Massachusetts, this appliance must be
installed in compliance with Massachusetts Fuel Gas and
Plumbing Code CMR 248.
1. IMPORTANT: All plumbing installations must be performed by
a qualied plumber.
2. For units equipped with a DRAIN LINE: Some jurisdictions
may require an approved air gap or other back-ow prevention
device in the drain. It is the responsibility of the plumber to
determine such requirement, to provide and
properly install the
required device.
3. For SS-4, SS-8 and SS-10 DRAIN LINE units, the drain must
be attached with a union at the drain line tting. This is
necessary to provide for future maintenance of the heating
element.
NOTE: Damage caused
by leaks due to improper
installation is NOT covered by
warranty.
CAUTION:
SHOCK HAZARD
The ground lug of this
appliance must be connected
to a suitable building ground.
IMPORTANT:
Contact a licensed
electrician to install and
connect electrical power to
the appliance.
IMPORTANT:
Damage due to being
connected to the wrong
voltage or phase is NOT
covered by warranty.
IMPORTANT: Electrical
installation other than as
specied on the specication
sheet will void the UL listing,
and may void the warranty.
NOTE: Plumb connections
must be made in compliance
with all Federal, State and
Local Plumbing Codes and
Ordinances.
M011D.01 2M-308027 Owners Manual for Built-In Round T’Stat Warmers