Specifications
INSTALLATION 
5
 4.  For “top-mounted” warmers (i.e. warmers mounted from above  
the counter top):
    a.  Verify that provided sealants are applied to the underside 
  of the warmer top ange prior to setting the unit into the 
  cutout.
    b.  After installation, verify that the tabs on the Wellsloks are 
  turned out to lock the warmer into the counter
    c.  Apply a thin bead of food-grade silicone sealant around the 
  ange to seal it to the counter.
    d.  Wellslok extension kits are available for installing warmers 
  in counter tops where the standard Wellslok would not  
  normally reach. The extension kit will adapt to counter tops 
  up to 1¾” thick.
ELECTRICAL INSTALLATION
 1.  Refer to the product nameplate. Verify the electrical service 
power. Voltage and phase must match the nameplate 
specications. Wiring the warmer to the wrong voltage can 
severely damage the unit or cause noticeably decreased 
performance. 
 2.  Available electrical service amperage must meet or exceed the 
specications listed on the specication sheet provided with the 
warmer.
 3.  Warmer and control unit must be connected to an appropriate 
building ground. Ground connection will be marked “GND” or 
” “ .
NOTE: Wire gauge, insulation type and temperature rating , as 
well as type, size and construction of conduit, must meet or exceed 
applicable specications of local codes and of the National 
Electrical Code.
PLUMBING INSTALLATION
For use in the State of Massachusetts, this appliance must be 
installed in compliance with Massachusetts Fuel Gas and 
Plumbing Code CMR 248.
 1.  IMPORTANT:  All plumbing installations must be performed by 
a qualied plumber.
 2.  For SS4D, SS-8D and SS10D drainline units, some 
jurisdictions may require an approved air gap or other 
back-ow prevention device in the drain. It is the responsibility 
of the plumber to determine such requirement, to provide and 
properly install the required device.
 3.  For SS4D, SS8D and SS10D drainline units, the drain must be 
attached with a union at the drain line tting. This is necessary 
to provide for future maintenance of the heating element.
NOTE: Damage caused by 
leaks due to improper
installation is NOT covered by 
warranty. 
CAUTION:
SHOCk HAzARD
The ground lug of this 
appliance must be connected 
to a suitable building ground.
IMPORTANT:
Contact a licensed electrician 
to install and connect electrical 
power to the appliance.
IMPORTANT:
Damage due to being 
connected to the wrong 
voltage or phase is NOT 
covered by warranty.
IMPORTANT:  Electrical 
installation other than as 
specied on the specication 
sheet will void the UL listing, 
and may void the warranty. 
NOTE: Plumb connections 
must be made in compliance 
with all Federal, State and 
Local Plumbing Codes and 
Ordinances.
2M-308034; Drop-In Round Warmer w/Innite Switch Control
2M-308034; Drop-In Round Warmer w/Innite Switch Control