Specifications

M011B.03 2M-308016 Owners Manual for Unshrouded Drop-In Bottom Mounted Warmers w/T-Stat Controls
FEATURES & OPERATING CONTROLS
2
A. THERMOSTAT
1. On THERMOSTATICALLY CONTROLLED warmers, power is
applied to the heating element according to the control knob
position and the actual temperature at the temperature sensing
thermobulb.
2. The desired temperature is controlled by rotating the
TEMPERATURE CONTROL KNOB. The knob has a numeric
scale, where higher numbers correspond to higher temperature.
3. On warmers equipped with an INDICA
TOR LIGHT, the light will
glow when the thermostat is calling for heat (i.e. the element is
energized).
4. The
TEMPERATURE CONTROL KNOB will rotate approximately
300º, and will reach a “stop” at both ends.
The OFF position is marked.
NOTE: The dial position is an indication of the temperature setting.
Actual temperature will vary depending upon the type of product and
food consistency.
B. MOUNTING
1. Drop-in warmers (i.e. SS206T) are equipped with wellsloks,
uniquely designed turnout tabs which help secure the warmer top
ange to the countertop.
2. Bottom-mounted warmers (i.e. SS206ET) require that the cutout
be anged to provide a mounting means.
3. See the Installation Instructions, supplied with the particular
appliance, for details.
C. DRAINS
1. Sufx “D” units (e.g. SS206TD) have drains for each pan,
with each pan having an individual drain valve.
INDICATOR
LIGHT
TEMPERATURE
CONTROL
KNOB
IL2468
IL2469
WELLSLOKS