Specifications

M011B.03 2M-308016 Owners Manual for Unshrouded Drop-In Bottom Mounted Warmers w/T-Stat Controls
TROUBLESHOOTING SUGGESTIONS
10
There are no user-serviceable components in this appliance.
In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
No power to warmer Circuit breaker off or tripped Reset circuit breaker
Warmer will not heat Temperature control not set Set control to desired temperature
Warmer trips circuit breaker
Wet insulation
Verify ange-to counter seal is sound,
or reseal with food-grade silicone
sealant
Pan leaking or other internal damage
Contact your Authorized Wells
Service Agency for repairs
Internal damage
Contact your Authorized Wells
Service Agency for repairs
Warmer slow to heat
Mineral deposits on pan acting as a insulator Clean pan(s) with delime cleaner
Wired to wrong voltage
Verify supply voltage - must match
voltage on warmer nameplate
Drain-equipped unit will not hold
water
Drain valve not fully closed
Check drain valve for debris and
close fully
Drain valve damaged or pan(s) leaking
Contact your Authorized Wells
Service Agency for repairs
Auto-ll unit overows
Water level sensor dirty Clean water level sensor
Internal damage
Contact your Authorized Wells
Service Agency for repairs
Auto-ll unit does not ll
Water supply turned off or restricted
Be sure water supply is turned on and
water supply hose is not pinched or
twisted
Bad Probe or other Internal Damage
Contact your Authorized Wells
Service Agency for repairs
One or more pans of an auto-ll unit
do not ll
Blocked drain manifold Clean drain manifold