Specifications

FEATURES & OPERATING CONTROLS
2
A. INFINITE SWITCH
On INFINITE SWITCH CONTROLLED warmers, power is applied
to the heating element based on the control knob position, which
varies the duty cycle of the heating element.
The desired temperature is controlled by rotating the TEMPERA-
TURE CONTROL KNOB. The knob may have a numeric scale,
where higher numbers correspond to higher temperature. LO is
the lowest temperature setting; PREHEAT is a “continuous on”
setting. Innite switch controlled warmers are equipped with a
hi-limit device to prevent overheating. The hi-limit will self-reset
after the warmer has cooled.
On warmers equipped with an INDICATOR LIGHT, the light will
glow when the innite switch is in any position other than OFF.
The TEMPERATURE CONTROL KNOB will rotate without
stopping, with PREHEAT and OFF having obvious detents. The
OFF position is a “positive” OFF (i.e. the switch is positively held
in the open position).
NOTE: An innite switch controls temperature by varying the ratio
of “on” time to “off” time. Thus, no temperature sensing devise is
required.
B. MOUNTING
Top-mounted built-in warmers (i.e SS206) are equipped with
WELLSLOKS, uniquely designed turnout tabs which help secure
the warmer top ange to the countertop.
Bottom-mounted warmers (i.e SS206E) require that the cutout
be anged to provide a mounting means.
See the Installation Instructions, supplied with the particular
appliance, for details.
C. DRAINS
“D” units (e.g. SS206D) have drains for each pan, with each pan
having an individual drain valve.
1.
2.
3.
4.
1.
2.
3.
1.
IMPORTANT:
DO NOT LEAVE ON “PRE-
HEAT”
Unit may cycle on hi-limit
control, leading to premature
failure of the hi-limit control
device.
M012B.01 2M-308028 Owners Manual for SS206 Built-In Inf Sw. Warmers
M012B.01 2M-308028 Owners Manual for SS206 Built-In Inf Sw. Warmers