011C WELLS BLOOMFIELD, LLC 10 Sunnen Dr., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www.wellsbloomfield.
LIMITED WARRANTY STATEMENT Unless otherwise specified, all commercial cooking equipment manufactured by WELLS BLOOMFIELD, LLC is warranted against defects in materials and workmanship for a period of one year from the date of original installation or 18 months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser only. The prices charged by Wells Bloomfield for its products are based upon the limitations in this warranty.
TABLE OF CONTENTS WARRANTY SPECIFICATIONS FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY LISTING INFORMATION INSTALLATION OPERATION CLEANING INSTRUCTIONS TROUBLESHOOTING SUGGESTIONS MAINTENANCE INSTRUCTIONS MODEL NUMBER IDENTIFICATIONS EXPLODED VIEW & PARTS LIST WIRING DIAGRAM PARTS & SERVICE CUSTOMER SERVICE DATA xi 1-3 4 5 5 6 8 10 12 13 14 15 - 25 26 - 35 36 37 INTRODUCTION Thank You for purchasing this Wells Bloomfield appliance.
SPECIFICATIONS (Thermostat) MOD-200T MOD-200TD MOD-200TDM MOD-200TN MOD-200TDN MOD-200TDMN MOD-227TD MOD-227TDM MOD-300T MOD-300TD MOD-300TDM MOD-300TN MOD-300TDN MOD-300TDMN MOD-327TDM MOD-400T MOD-400TD MOD-400TDM MOD-427TDM MOD200TDM/AF MOD200TDMN/AF MOD227TDM/AF MOD300TDM/AF MOD300TDMN/AF MOD327TDM/AF MOD400TDM/AF MOD427TDM/AF MOD500TDM/AF MOD527TDM/AF VOLTS WATTS 208 VAC AMPS 3ø AMPS1ø L1 L2 L3 2480W 6.0A 6.0A 10.3A 11.9A 240 VAC 3300W 6.9A 6.9A 11.9A 13.8A 208 VAC 2480W 6.
SPECIFICATIONS (Digital) M011C.
FEATURES & OPERATING CONTROLS TEMPERATURE CONTROL KNOB IL2468 IMPORTANT: DO NOT LEAVE ON “PREHEAT” Unit may cycle on hi-limit control, leading to premature failure of the hi-limit controls device. WELLSLOKS IL2469 WATER LEVEL SENSOR A. INFINITE SWITCH 1. On INFINITE SWITCH CONTROLLED warmers, power is applied to the heating element based on the control knob position, which varies the duty cycle of the heating element. 2. The desired temperature is controlled by rotating the TEMPERATURE CONTROL KNOB.
PRECAUTIONS AND GENERAL INFORMATION This appliance is intended for use in commercial establishments only. WARNING: WA This appliance is intended to hold pre-heated food for human consumption. No other use is recommended or authorized by the manufacturer or its agents. SHOCK HAZARD SHO Operators of this appliance must be familiar with the appliance use, limitations and associated restrictions. Operating instructions must be read and understood by all persons using or installing this appliance.
INSTALLATION WARNING: WA RISK OF INJURY RIS Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical and plumbing codes. Failure can result in personal injury and property damage. CAUTION CA FIRE HAZARD Avoid storin storing flammable or combustible materials in, on or near the appliance.
INSTALLATION 3. For “top-mounted” warmers (i.e. warmers mounted from above the counter top): a. Verify that provided sealants are applied to the underside of the warmer top flange prior to setting the unit into the cutout. b. After installation, verify that the tabs on the Wellsloks are turned out to lock the warmer into the counter. c. Apply a thin bead of food-grade silicone sealant around the flange to seal it to the counter. d.
OPERATION HOT SURFACE H Exposed su surfaces can be hot to the touch and may cause burns. CAUTION: CA SHOCK HAZARD SHO DO NOT splash or pour water onto control panel or wiring. Always use an inset. DO NOT place food directly into the warmer. Always pour hot water into the warmer before it is preheated. DO NOT pour water into a dry, heated warmer. This may damage the unit. DO NOT put ice into a warmer pan. This will cause condensation on the inside of the warmer.
OPERATION (continued) AUTOFILL WARMERS continued 6. DO NOT use autofill warmers in the dry mode. This may damage the water level sensor probe. NEVER turn the thermostat ON for the pan with the probe and fill tube unless the entire warmer unit is to be used in the wet mode. 7. Clean water level sensor daily to maintain water level in warmer. OPERATION 1. Always use an inset. DO NOT place food directly into the warmer. 2. Check water level in wet-operation warmer frequently during use.
CLEANING INSTRUCTIONS CAUTION: CA SHO SHOCK HAZARD DO NOT splash spl or pour water into or over any control panel or wiring. CAUTION: CA SHOCK HAZARD SH DAILY CLEANING INSTRUCTIONS PREPARATIONS: Turn control knob(s) to OFF. Allow warmer to cool before proceeding. Remove any insets, pans and/or adapter tops. Drain or remove water from well if used for wet operation. FREQUENCY: Minimum - daily.
CLEANING INSTRUCTIONS WEEKLY CLEANING INSTRUCTIONS CAUTION: CA M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers PREPARATIONS: Remove any insets, pans and/or adapter tops. Drain or remove water from well if used for wet operation. FREQUENCY: Weekly, or whenever lime or scale is seen accumulating on the sides of the warmer pans. TOOLS: Commercial Delime Cleaner Plastic Scouring Pad Clean Cloth or Sponge 1.
TROUBLESHOOTING SUGGESTIONS POSSIBLE CAUSE SUGGESTED REMEDY Circuit breaker off or tripped Reset circuit breaker Warmer will not heat Temperature control not set Set control to desired temperature Wet insulation Verify flange-to counter seal is sound, or reseal with food-grade silicone sealant Pan leaking or other internal damage Contact your Authorized Wells Service Agency for repairs Internal damage Contact your Authorized Wells Service Agency for repairs Mineral deposits on pan acting as a i
MAINTENANCE INSTRUCTIONS CARE OF STAINLESS STEEL Stainless steel is a marvelous material: strong, lustrous and low maintenance. With a minimum of care, it will normally retain its beauty and durability for the life of the equipment. In some applications, however, special care is required in order to maintain stainless steel’s special properties. External components, such as cabinets and control panels, are finished with a grain pattern.
MODEL NUMBER IDENTIFIER MOD200T, MOD200TD, MOD200TDM Built-In Modular Warmer Identifier M300CTDNMAF6 96” Capillary Tube Auto-Fill Manifold Narrow Drain T=Thermostat, E=Digital Niether = Infinite Corded 00= 20” Pan, 27=27” Pan Number of Pans M or MOD, same Standard M011C.
EXPLODED VIEW & PARTS LIST 36 32 1 35 31 33 3 34 6 “T”units only 7 2 8 3 9 4 10 5 30 29 M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers 16 25 24 11 17 12 13 15 14 25 24 23 22 27 21 28 18 26 20 10 19 See Detail A Digital Controlled Units = AutoFill Units Only SK2615, BUILT-IN MODULAR WARMERS 15 Rev.
PARTS LIST: M200-227 SERIES Model: Modular Warmers M200-227T, TD, TDM, TDMAF, TN, M200-227E, CE, ED, EDM, EDMAF, EN 1 2 3 Part No Description Qty SCREEN DRAIN ASSY WARMER P2-Z14636 PAN ASSY 12X20 EAF W/TEE P2-Z14647 PAN ASSY 12X27 EAF P2-WL0064 PAN ASSY W/ELBOW MODTDMN WS-503893 PAN ASSY 200-500TDM A/F M200 T-STAT & INFINITE WS-504101 PAN ASSY 12X27 AF M227 T-STAT P2-Z14639 PAN ASSY 12X20 E M200 DIGITAL P2-Z14637 PAN ASSY 12X20 ED w/DRAIN P2-Z14638 PAN ASSY 12X20 EDM P2-Z14646 PAN
PARTS LIST: M200-227 SERIES Model: Modular Warmers M200-227T, TD, TDM, TDMAF, TN, M200-227E, CE, ED, EDM, EDMAF, EN Fig No 21 Description BRKT MTG THERMO INFINITE P2-48176 BRKT THERMO MOD200TDM AUT Qty 2 Application T-STAT & INFINITE UNITS T-STAT AUTOFILL 22 2E-306865 CONTROL LIQ LEVEL 208/240 1 AUTOFILL UNITS 23 2I-40034 GROMMET SCREW T4 4 AUTOFILL UNITS 24 2K-33996X FTG FLEX CONDUIT 90X3/8 2 25 2I-Z12311 GASKET-FIBER WASHER 2 P2-300712 COVER BOT M227-427TDM/AM 2 P2-35004 COVER
PARTS LIST: M300-327 SERIES Model: Modular Warmers M300-327T, TD, TDM, TDMAF, TN, M300-327E, CE, ED, EDM, EDMAF, EN 1 2 3 Part No P2-31869 Description Qty SCREEN DRAIN ASSY WARMER 3 Application DRAIN UNITS P2-Z14636 PAN ASSY 12X20 EAF W/TEE M300 DIGITAL P2-Z14647 PAN ASSY 12X27 EAF M327 DIGITAL P2-WL0064 PAN ASSY W/ELBOW MODTDMN WS-503893 PAN ASSY 200-500TDM A/F M300 T-STAT & INFINITE WS-504101 PAN ASSY 12X27 AF M327 T-STAT P2-Z14639 PAN ASSY 12X20 E M300 DIGITAL P2-Z14637 PAN ASS
PARTS LIST: M300-327 SERIES Model: Modular Warmers M300-327T, TD, TDM, TDMAF, TN, M300-327E, CE, ED, EDM, EDMAF, EN Fig No 21 Description BRKT CONT MTG MOD 300 400 P2-48586 BRKT THERMO MOD300T Qty Application INFINITE UNITS 1 T-STAT P2-47863 BRKT THERMO MOD BMW ROHS 22 2E-306865 CONTROL LIQ LEVEL 208/240 1 AUTOFILL UNITS 23 2I-40034 GROMMET SCREW T4 4 AUTOFILL UNITS 24 2K-33996X FTG FLEX CONDUIT 90X3/8 2 25 2I-Z12311 GASKET-FIBER WASHER 2 P2-300702 COVER BOT M327/ 527TDM/A P2-3
PARTS LIST: M400-427 SERIES Model: Modular Warmers M400-427T, TD, TDM, TDMAF, M400-427E, CE, ED, EDM, EDMAF Description Qty P2-31869 SCREEN DRAIN ASSY WARMER 4 P2-Z14636 PAN ASSY 12X20 EAF W/TEE P2-Z14647 PAN ASSY 12X27 EAF WS-503893 PAN ASSY 200-500TDM A/F WS-504101 PAN ASSY 12X27 AF M427 T-STAT P2-Z14639 PAN ASSY 12X20 E M400 DIGITAL P2-Z14637 PAN ASSY 12X20 ED w/DRAIN P2-Z14638 PAN ASSY 12X20 EDM P2-Z14646 PAN ASSY 12X27 EDM WS-55741 PAN W/O DRAIN 200-500 / T WS-53201 PAN W/DRAI
PARTS LIST: M400-427 SERIES Model: Modular Warmers M400-427T, TD, TDM, TDMAF, M400-427E, CE, ED, EDM, EDMAF Fig No Description Qty Application 2T-38968 THERMO K TYPE 2T-46551 THERMO CTRL 96IN CAP 2T-45917 THERMO CTRL W/AUX WARMERS 2E-30570 SWITCH INFINITE, 120V 2E-30562 SWITCH INFINITE, 240V 2R-44373 KNOB CONTROL ASSY WARMERS 2R-40498 KNOB ASSY MOD 100DT 2E-46529 SOLENOID VALVE 1/4NPT 240 1 AUTOFILL UNITS P2-40843 BRKT MTG THERMO INFINITE 2 T-STAT (SPLIT CONTROL) P2-48176 BRKT THE
PARTS LIST: M500-527 SERIES Model: Modular Warmers M500-527T, TD, TDM, TDMAF, M500-527E, CE, ED, EDM, EDMAF 1 2 Description Qty P2-31869 Part No SCREEN DRAIN ASSY WARMER 5 P2-Z14636 PAN ASSY 12X20 EAF W/TEE P2-Z14647 PAN ASSY 12X27 EAF WS-503893 PAN ASSY 200-500TDM A/F WS-504101 PAN ASSY 12X27 AF P2-Z14639 PAN ASSY 12X20 E P2-Z14637 PAN ASSY 12X20 ED w/DRAIN P2-Z14638 PAN ASSY 12X20 EDM P2-Z14646 PAN ASSY 12X27 EDM WS-55741 PAN W/O DRAIN 200-500 / T WS-53201 PAN W/DRAIN 200-500 /T
PARTS LIST: M500-527 SERIES Model: Modular Warmers M500-527T, TD, TDM, TDMAF, M500-527E, CE, ED, EDM, EDMAF Fig No Description Qty Application 2R-44373 KNOB CONTROL ASSY WARMERS 2R-40498 KNOB ASSY MOD 100DT 2E-46529 SOLENOID VALVE 1/4NPT 240 1 AUTOFILL UNITS P2-48285 BRKT THERMO MOD400 1 M500-527, T-STAT P2-40843 BRKT MTG THERMO INFINITE 2 MOD500TDMFA(6), MOD527TDMAF(6) (SPLTI) P2-47863 BRKT THERMO MOD 1 MOD500TDMFA(6), MOD527TDMAF(6) (SPLTI) P2-37809 BRKT CONT MTG MOD 1 M500 INFI
EXPLODED VIEW: DETAIL A 3 2 1 4 5 6 3 18 3 17 7 9 13 Nameplate 12 11 8 10 14 15 SOME ITEMS ARE A REPRESENTATION OF THE ACTUAL APPREANCE DUE TO YOUR SPECIFIC MODEL. Detail A MODE - EAF Digital Control Fab Warmer IL2523, Rev. -, 8/21/12 24 M011C.
PARTS LIST: DETAIL A Detail A: Digital Control Box Assy Fig No Description Application 1 2A-Z3429 SPACER-NYLON .175X.375X.
WIRING DIAGRAM: Infinite Control Units WIRING DIAGRAM FOR MODULAR 200 WARMER 208/240V SINGLE PHASE SER. NO. WM 1000 & UP ELEMENT (2) SAFETY THERMO (2) 7 5 6 8 H2 H1 P L1 INFINITE SWITCH (2) L2 H2 H1 P L1 L2 4 PILOT LIGHT (2) SINGLE PHASE L1 2 L3 3 L2 1 VOLTS AMPS 208 240 8.7 10.0 TERM. BLOCK REV. I PN 2M-31222 WIRING DIAGRAM FOR MODULAR 300 WARMER 208/240V SINGLE PHASE OR THREE PHASE SER. NO.
WIRING DIAGRAM: Infinite Control Units WIRING DIAGRAM FOR MODULAR 400 WARMER 208/240V SINGLE PHASE OR THREE PHASE SER. NO. MOD-400 MW 1250 & UP 8 ELEMENT (4) 6 L1 4 2 SAFETY THERMO (4) 11 P H2 16 H2 H1 L2 L1 17 7 5 14 H1 PILOT LIGHT (4) 15 13 12 P L1 INFINITE SWITCH (4) L2 4 2 18 H2 H1 P L1 L2 L2 3 P L1 SINGLE PHASE 1 H2 H1 L2 8 5 THREE PHASE 3 1 4 L1 2 L3 6 5 7 NOM. AMPS PER LINE THREE PHASE SINGLE L1 L2 L3 PHASE VOLTS 208 240 11.2 13.0 11.2 13.0 7.5 8.
WIRING DIAGRAM: Electronically Control Units NOTES: WIRING DIAGRAM MOD200E 1) TEMPERATURE AND WATER LEVEL SENSOR WIRES ROUTE SEPARATELY IN SMALLER CONDUIT. 2) GROUND TO EARTH USING SUPPLIED STUD IN CONTROL BOX. 3) OPTIONAL WATER LEVEL CONTROL: WIRES 19 & 35 SHOULD BE CAPPED IF NOT USED. MODEL V 3& WATTS MOD400E 208 50/60 Hz 240 4 19 3 PROBE 2 COM 38 1 36 35 ALTERNATE WATER LEVEL CONTROL 1& 6.0 10.3 6.0 11.9 6.9 11.9 6.9 13.
WIRING DIAGRAM: Electronically Control Units NOTES: WIRING DIAGRAM MOD400E 1) TEMPERATURE AND WATER LEVEL SENSOR WIRES ROUTE SEPARATELY IN SMALLER CONDUIT. 2) GROUND TO EARTH USING SUPPLIED STUD IN CONTROL BOX. 3) OPTIONAL WATER LEVEL CONTROL: WIRES 19 & 35 SHOULD BE CAPPED IF NOT USED. L1= 6 37 34 9 3 12 101 19 4 35 2 V WATTS MOD400E 208 240 4960 6600 3& 1& L3 L1 L2 36 1 MODEL 7 1 10 102 38 3 PROBE COM L2= 4 ALTERNATE WATER LEVEL CONTROL 14.5 9.8 14.5 23.8 17.8 11.3 17.8 27.
WIRING DIAGRAM: MOD200 Thermostat Control Units WIRING DIAGRAM FOR MOD 200T, 227T WARMER 208/240V, SINGLE PHASE HEATING ELEMENT (2) 5 6 2 3 PILOT LIGHT (2) THERMOSTAT (2) 1 4 WIRE CONNECTOR 7 3 6 7 SINGLE PHASE WATTS 208 2480 11.9 240 3300 13.8 REV. C L3 50 HZ 60 1 P/N 2M-40844 L2 4 TERM.
WIRING DIAGRAM: MOD300 Thermostat Control Units WIRING DIAGRAM FOR MOD 300T, 327T WARMER 208/240V, SINGLE & THREE PHASE HEATING ELEMENT (3) 8 9 6 5 3 2 PILOT LIGHT (3) PILOT LIGHT PL 3 THERMOSTAT (3) 6 L1 12 9 7 1 4 L3 1 L2 4 TERMINAL BOARD 7 WIRE CONNECTOR 12 6 SINGLE PHASE 12 9 L1 3 L3 THREE PHASE VOLTS SINGLE PHASE L1 L2 L3 208 10.3 240 11.9 10.3 11.9 10.3 11.9 7 50 17.9 1 HZ L2 4 60 20.6 TERM. BLOCK REV. E P/N 2M-48589 M011C.
WIRING DIAGRAM: MOD400 Thermostat Control Units WIRING DIAGRAM FOR MOD 400T, 427T WARMER 208/240V, SINGLE & THREE PHASE 14 6 HEATING ELEMENT (4) 3 13 11 12 9 8 6 5 L1 12 2 3 9 15 PILOT LIGHT (4) L3 10 THERMOSTAT (4) 1 10 7 L2 4 1 4 TERMINAL BOARD 7 SINGLE PHASE WIRE CONNECTOR 13 14 15 15 12 3 6 13 L1 4 9 14 THREE PHASE VOLTS L1 L2 L3 208 14.5 240 17.8 14.5 17.8 9.8 11.3 SINGLE PHASE 23.8 HZ 1 60 27.5 REV. F L3 10 50 L2 7 P/N 2M-48599 TERM.
WIRING DIAGRAM: MOD400 Thermostat Control Units WIRING DIAGRAM FOR MOD400TDM & 427TDM WARMER W/AUTO WATER FILL 208/240V, SINGLE & THREE PHASE HEATING ELEMENT (4) WATER PAN PILOT LIGHT PROBE GRN 51 50 5 4 6 7 8 9 10 19 MALE/FEMALE CONNECTOR WIRE CONNECTOR THERMOSTAT 11 12 13 14 THERMOSTAT 15 22 33 28 27 9 22 37 6 19 3 PROBE 2 36 34 L3 COM L3 32 29 29 12 10 L2 4 1 L1 13 7 4 38 35 28 L1 L2 35 LOW WATER CONTROL TERM.
WIRING DIAGRAM: MOD500 Thermostat Control Units WIRING DIAGRAM FOR MOD 500T, 527T WARMER 208/240V, SINGLE & THREE PHASE 18 20 15 6 HEATING ELEMENT (5) 3 16 15 14 12 11 8 9 5 6 L1 12 9 2 3 PILOT LIGHT (5) 17 L3 10 THERMOSTAT (5) 1 L2 4 13 10 7 1 4 TERMINAL BOARD 13 7 SINGLE PHASE 17 WIRE CONNECTOR 20 18 16 16 18 6 9 15 L1 3 7 10 THREE PHASE VOLTS L1 208 14.6 240 16.9 SINGLE PHASE L2 L3 14.6 16.9 19.5 29.8 22.1 34.4 L3 13 20 50 1 HZ 60 L2 4 TERM.
WIRING DIAGRAM: MOD500 Thermostat Control Units WIRING DIAGRAM FOR MOD 500TDM AND 527TDM WARMER W/AUTO WATER FILL 208/240V, SINGLE & THREE PHASE HEATING ELEMENT (5) PILOT LIGHT 14 15 13 12 11 10 9 8 7 6 5 4 3 2 1 THERMOSTAT WIRE CONNECTOR 35 20 SINGLE PHASE 27 L3 13 L2 12 30 LOW WATER CONTROL 31 L3 WATER FILL VALVE 33 6 28 MALE/FEMALE CONNECTOR 20 3 THREE PHASE 208 240 38 35 37 TERM.
PARTS & SERVICE DESCRIPTION PART NO. ADAPTERS & INSETS ADAPTER TOP, convert 12” x 20” warmer to hold two 7 qt. insets WS-21502 ADAPTER TOP, convert 12” x 20” warmer to hold two 4 qt. and two 2½ qt DD-21503 ADAPTER TOP, convert 12” x 20” warmer to hold three 4 qt. insets DD-21616 ADAPTER TOP, convert 12” x 20” warmer to hold one 7qt. and one 4 qt. DD-21618 ADAPTER TOP, convert 12” x 20” warmer to hold four 2½ qt. insets WS-21623 ADAPTER TOP, convert 12” x 27” SMPT-27 to hold three 7 qt.
PARTS & SERVICE DESCRIPTION PART NO. ACCESSORIES WELLSLOK EXTENSION KIT, for UL LISTED circular warmers only, adapt to wood counter up to 1¾” thick WS-22592* WELLSLOK EXTENSION KIT, for UL LISTED 12” x 20” warmers only, adapt to wood counter up to 1¾” thick WS-22593* For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call: Wells Bloomfield, LLC 10 Sunnen Dr. St.
WELLS BLOOMFIELD, LLC 10 Sunnen Dr., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www.wellsbloomfield.