TROUBLESHOOTING SUGGESTIONS 
10 
SYMPTOM  POSSIBLE CAUSE  SUGGESTED REMEDY 
No power to warmer  Circuit breaker off or tripped  Reset circuit breaker 
Warmer will not heat  Temperature control not set  Set control to desired temperature 
Warmer trips circuit breaker 
Wet insulation 
Verify flange-to counter seal is 
sound, or reseal with food-grade 
silicone sealant 
Pan leaking or other internal damage 
Contact your Authorized Wells 
Service Agency for repairs 
Internal damage 
Contact your Authorized Wells 
Service Agency for repairs 
Warmer slow to heat 
Mineral deposits on pan acting as a 
insulator 
Clean pan(s) with delime cleaner 
Wired to wrong voltage 
Verify supply voltage - must match 
voltage on warmer nameplate 
Drain valve not fully closed 
Check drain valve for debris and 
close fully 
Drain valve damaged or pan(s) 
leaking 
Contact your Authorized Wells 
Service Agency for repairs 
Drain-equipped unit will not hold 
water 
There are no user-serviceable components in this appliance. 
In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs. 
WIRING DIAGRAM 
 M012C.04 2M-308032  Owners Manual for Four-Well Inf.Sw. MOD-Warmers 