Owner`s manual
pg 6 of 12
MODEL 400
PRODUCTS CORPORATION
33 ANDERSON ROAD, MIDDLETOWN, CONNECTICUT 06457--4926
UNITED STATES OF AMERICA E--MAIL. j
arvis.products.corp@snet.net
FAX 860--347--6978 TEL. 860--347--7271 WWW. jarvisproducts.com
JARVIS
6205005:::.
®
SPECIFICATIONS
Motor Power 1 hp 745 W
Operating Volt/Amp 230V/7.5A, 1 phase, 50/60 Hz
115V/15A, 1 phase, 50/60 Hz
Stroke 1.13 in 29 mm
Blade Speed 8000 strokes / min
Control Handle Single Trigger Electric
Blade Length 8 in 203 mm
16 in 406 mm
Overall Length (16 in blade) 32 in 813 mm
Weight (without blade) 9.8 lbs 4.5 kg
INSTALLATION INSTRUCTIONS
These instructions have been prepared to assure you of
satisfactory operation through proper use of your Jarvis
Wellsaw.
Read them carefully and keep them for future refer
ence.
POWER SUPPLY
Your Jarvis Wellsaw operates on 50 or 60 Hz., single
phase alternating current. Its voltage rating is indicated
on the name plate (either 115 or 230 Volt). If an exten-
sion cord is to be used, be sure that the wire size is ade -
quate to maintain full line voltage to the tool.
GROUNDING
Your Jarvis Wellsaw should be grounded to prevent the
user from electric shock or electrocution.TheJarvis
Wellsaw is equipped with an approved three conductor
cord and three prong grounding--type plug to fit the prop-
er grounding--type receptacle. The green conductor in
the cord is the grounding wire. Never connect the green
wire to a live terminal. If your Jarvis Wellsaw is the 115
volt model, it has a plug that looks like figure ”A”. If
your Jarvis Wellsaw is the 230 volt model, it has a plug
that looks like figure ”B”.
figure A figure B
grounding blade grounding blade
Do not use any adapters with the Jarvis Wellsaw
EXTENSION CORDS
Make sure your extension cord is in good condition.
When using an extension cord, be sure to use one heavy
enough to carry the current your Jarvis Wellsaw will
draw. An undersized cord will cause a drop in line volt-
age resulting in loss of power and overheating. The table
below shows the correct size to use depending on cord
length and nameplate ampere rating. If in doubt, use the
next heavier gage. The smaller the gage number, the
heavier the cord.
Minimum Wire Gage for Extension Cords
Volts TotalLengthofCordinFeet
120 0--25 26--50 51--100 101--150
240
0--50 51--100 101--200 201--300
Amp Rating Wire Size (AWG)
0--6 18 16 16 14
6--10
18 16 14 12
When tool is used outdoors, use only extension cords la-
beled for outdoor use.
installation instructions