Specifications
M011C.02 2M-Z16298 Owners Manual for Built-In Well Modular Warmers
INSTALLATION
ELECTRICAL INSTALLATION
 1.  Refer to the product nameplate. Verify the electrical service 
power. Voltage and phase must match the nameplate   
specications. Wiring the warmer to the wrong voltage can  
severely damage the unit or cause noticeably decreased   
performance. 
 2.  Available electrical service amperage must meet or exceed the 
specications listed on the specication sheet provided with the 
warmer.
 3.  Warmer and control unit must be connected to an appropriate 
building ground. Ground connection will be marked “GND” or 
” “ .
NOTE: Wire gauge, insulation type and temperature rating , as 
well as type, size and construction of conduit, must meet or exceed 
applicable specications of local codes and of the National 
Electrical Code.
PLUMBING INSTALLATION
For use in the State of Massachusetts, this appliance must be 
installed in compliance with Massachusetts Fuel Gas and 
Plumbing Code CMR 248.
 1.  IMPORTANT:  All plumbing installations must be performed by 
a qualied plumber.
 2.  For units equipped with a DRAIN LINE: Some jurisdictions  
may require an approved air gap or other back-ow   
prevention device in the drain. It is the responsibility of the 
plumber to determine such requirement, to provide and 
properly install the required device.
 3.  AUTOFILL units are equipped with a DRAIN LINE: Some 
jurisdictions may require an approved air gap or other back-
ow prevention device in the drain. It is the responsibility of the 
plumber to determine such requirement, to provide and properly 
install the required device.
 4.  For AUTOFILL units: Some jurisdictions may require an 
approved back-ow preventer in the water supply line. It is the 
responsibility of the plumber to determine such requirement, and 
to provide and properly install the required device.
    Autoll supply must be connected to a COLD WATER line only.
IMPORTANT:
While local plumbing codes may allow the use of pcv, cpvc, abs or 
other plastic pipe for drain connections. DO NOT attach a plastic 
drain to the bottom of the food warmer. These units will contain water 
with temperatures in excess of 180°F (82°C) and localized metal 
temperatures in excess of 275°F (135°C). Failure to follow these 
directions may result in personal injury and property damage.
NOTE: Damage caused 
by leaks due to improper 
installation is NOT covered by 
warranty. 
CAUTION:
SHOCK HAZARD
The ground lug of this 
appliance must be connected 
to a suitable building ground.
IMPORTANT: Contact a 
licensed electrician to install 
and connect electrical power 
to the appliance.
IMPORTANT: Damage due to 
being  connected  to  the  wrong 
voltage or phase is NOT 
covered by warranty.
IMPORTANT: Electrical 
installation other than as 
specied on the specication 
sheet will void the UL listing, 
and may void the warranty. 
NOTE:  Plumb connections 
must be made in compliance 
with all Federal, State and 
Local Plumbing Codes and 
Ordinances.
7