Operating instructions
DAILY CLEANING INSTRUCTIONS 
PREPARATIONS: Turn control knob(s) to OFF. Allow warmer to cool 
 before proceeding.  
          Remove any insets, pans and/or adapter tops. 
          Drain or remove water from well if used for   
 wet operation.  
FREQUENCY:  Minimum - daily. 
TOOLS:    Mild Detergent 
          Solution: 10 Parts Warm Water to 4 Parts Vinegar 
 Plastic Scouring Pad  
 Clean Cloth or Sponge  
 Food-Grade Silicone Sealant  
1. Wipe entire unit down using a clean cloth or sponge and mild 
  detergent. Carefully wipe any debris and residue from the water 
  level sensor (auto-fill units). 
2. Use a plastic scouring pad to remove any hardened food particles 
  or mineral deposits. IMPORTANT: Do NOT use steel wool for 
 cleaning. 
3. Rinse warmer thoroughly with a vinegar and water solution to 
  neutralize all detergent cleanser residue. 
4.  Inspect warmer flange-to-counter seal. Reseal with food-grade 
  silicone sealant if necessary. Failure to do so may allow grease and 
  water to leak into insulation and heating element, causing a potential 
  fire and/or electric shock hazard. 
5. Inspect warmer tank for damage. Damage to the outer body may 
  allow grease and water to leak into insulation and heating element, 
  causing a potential fire and/or electric shock hazard. Contact your 
  Authorized Wells Service Agency to inspect warmer if water or 
  grease contamination is suspected. 
6. Close drain valve. Add proper amount of warm water. Turn control 
  knob(s) ON and check for proper operation. 
CLEANING INSTRUCTIONS 
8 
 011 303308  OpManual for Built-In T’Stat Warmers 
CAUTION: 
SHOCK HAZARD 
Do NOT splash or pour water 
into or over any control panel 
or wiring. 
CAUTION: 
SHOCK HAZARD 
Disconnect warmer from 
electric power before cleaning 
CAUTION: 
BURN HAZARD 
Allow warmer to cool 
completely before cleaning. 