015 WELLS BLOOMFIELD, LLC 10 Sunnen Dr., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www.wellsbloomfield.
LIMITED WARRANTY STATEMENT Unless otherwise specified, all commercial cooking equipment manufactured by WELLS MFG. CO. is warranted against defects in materials and workmanship for a period of one year from the date of original installation or 18 months from the date of shipment from our factory, whichever comes first, and is for the benefit of the original purchaser only.
TABLE OF CONTENTS WARRANTY FEATURES & OPERATING CONTROLS PRECAUTIONS & GENERAL INFORMATION AGENCY LISTING INFORMATION INSTALLATION OPERATION CLEANING INSTRUCTIONS TROUBLESHOOTING SUGGESTIONS MAINTENANCE INSTRUCTIONS PARTS LIST PARTS & SERVICE CUSTOMER SERVICE DATA xi 2 3 3 4 6 7 9 10 12 & 13 16 17 INTRODUCTION Thank You for purchasing this Wells Manufacturing Co. appliance.
FEATURES & OPERATING CONTROLS (continued) A. THERMOSTAT OFF 95 35 180 82 75 24 70°F 21°C 205 96 WELLS 16 74 5 1. On THERMOSTATICALLY CONTROLLED warmers, power is applied to the heating element according to the control knob position and the actual temperature at the temperature sensing thermobulb. 2. The desired temperature is controlled by rotating the TEMPERATURE CONTROL KNOB. The knob has a numeric scale, where higher numbers correspond to higher temperature. 3.
PRECAUTIONS AND GENERAL INFORMATION This appliance is intended for use in commercial establishments only. This appliance is intended to heat cooked, refrigerated food for human consumption and to hold foods at serving temperature. No other use is recommended or authorized by the manufacturer or its agents. Operators of this appliance must be familiar with the appliance use, limitations and associated restrictions.
INSTALLATION NOTE: DO NOT discard the carton or other packing materials until you have inspected the appliance for hidden damage and tested it for proper operation. Refer to SHIPPING DAMAGE CLAIM PROCEDURE on the inside front cover of this manual. WARNING: RISK OF PERSONALINJURY Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical and plumbing codes. Failure can result in personal injury and property damage.
INSTALLATION (continued) 4. For Cook ‘N Hold warmers: a. Verify that provided sealants are applied to the underside of the warmer top flange prior to setting the unit into the cutout. b. After installation, verify that the tabs on the Wellsloks are turned out to lock the warmer into the counter c. Apply a thin bead of food-grade silicone sealant around the flange to seal it to the counter. d.
OPERATION CAUTION: Hot Surface Exposed surfaces can be hot to the touch and may cause burns. CAUTION: Electrical Shock Hazard DO NOT splash or pour water onto control panel or wiring. Always use an inset. DO NOT place food directly into the warmer. Always pour hot water into the warmer before it is preheated. DO NOT pour water into a dry, heated warmer. This may damage the unit. 2. The warmer is to be used for WET operation ONLY. Add approximately 1” of hot tap water before turning the warmer ON.
CLEANING INSTRUCTIONS DAILY CLEANING INSTRUCTIONS PREPARATIONS: Turn control knob(s) to OFF. Allow warmer to cool before proceeding. Remove any insets, pans and/or adapter tops ( if used). Drain or remove water from well if used for wet operation. FREQUENCY: Minimum - daily. TOOLS: Mild Detergent Solution: 10 Parts Warm Water to 4 Parts Vinegar Plastic Scouring Pad Clean Cloth or Sponge Food-Grade Silicone Sealant 1. Wipe entire unit down using a clean cloth or sponge and mild detergent. 2.
CLEANING INSTRUCTIONS (continued) FIRST AID EYES: In case of contact, immediately flush with warm water for 15 minutes and consult a physician SKIN: Wash with soap and water INHALATION: Relocate to fresh air. INGESTION: If swallowed, drink plenty of water or milk and consult a physician EMERGENCY PHONE (800) 255-3924 INGREDIENTS Sulfamic acid, citric acid, aluminum sulfate. Non-toxic when used as directed. WEEKLY CLEANING INSTRUCTIONS PREPARATIONS: Remove any insets, pans and/or adapter tops ( if used).
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY No power to warmer Circuit breaker off or tripped Reset circuit breaker Warmer will not heat Temperature control not set Set control to desired temperature Warmer trips circuit breaker Wet insulation Verify flange-to counter seal is sound, or reseal with food-grade silicone sealant Pan leaking or other internal damage Contact your Authorized Wells Service Agency for repairs Internal damage Contact your Authorized Wells Servic
MAINTENANCE INSTRUCTIONS CARE OF STAINLESS STEEL Stainless steel is a marvelous material: strong, lustrous and low maintenance. With a minimum of care, it will normally retain its beauty and durability for the life of the equipment. In some applications, however, special care is required in order to maintain stainless steel’s special properties. External components, such as cabinets and control panels, are finished with a grain pattern.
015 2M-303740 OpManual for Built-In HW NOTES 11
PARTS LIST: HW-106D 5P-21709 2N-35693UL, 120V 2N-35967UL, 240V WS-55992 D8-30291 Part of WS55984 2B-37946 WS-8706-109 Fitting Only 2I-Z12311 D8-35994 2I-Z12311 D8-37256 DD-35996 015 2R-35972 2K-31040 WS-55984 2J-35687 (Red) IL2027, Rev.
PARTS LIST: HSW/SMP-6D HW/SMP-6D D8-40516 D8-30291 2N-40457UL 208/240V 5P-21709 2B-37946 D8-44802 D8-40516 make from 2H-36196 (sold by the sq foot) make from 2H-36050 (sold by the sq foot) OpManual for Built-In HW 2K-33996X (CONDUIT FITTING ONLY) 2I-Z12311 2M-303740 P2-40629 2C-35736 015 2J-35687 OFF 70ºF 21ºC 5 20 6 9 75 24 2K-31040 2R-35972 2T-40509 93 35 180 82 WELLS 5 16 4 7 I7-Z12221 IL2273-PL015, Rev.
NOTES 015 2M-303740 OpManual for Built-In HW 14
015 2M-303740 OpManual for Built-In HW NOTES 15
PARTS & SERVICE Always use an inset. DO NOT place food directly into the warmer pan. DESCRIPTION PART NO. INSETS 4 QT. ROUND INSET w/ lid 5D-20774 7 QT. ROUND INSET w/ lid 5D-20587 11 QT. ROUND INSET w/ lid 5D-20908 11 QT. ROUND INSET w/ hinged lid 5D-21057 ADAPTER TOPS FOR HW-106D ONE 7 QT. INSET ADAPTER TOP 5D-20175 ONE 4QT. INSET ADAPTER TOP 5D-20822 ADAPTER TOPS FOR HW/SMP-6D TWO 7 QT. INSETS 5D-20176 1 TWO 4 QT. AND TWO 2 /2 QT. INSETS 5P-20434 THREE 4 QT. INSETS 5D-21615 ONE 7 QT.
PARTS & SERVICE (continued) DESCRIPTION PART NO.
WELLS BLOOMFIELD, LLC 10 Sunnen Dr., St. Louis, MO 63143 telephone: 314-678-6314 fax: 314-781-2714 www.wellsbloomfield.