Specifications
FEATURES & OPERATING CONTROLS
2
A.  THERMOSTAT
  1.  On thermostatically controlled warmers, power is applied to the 
heating element according to the control knob position and the 
actual temperature at the temperature sensing thermobulb. 
  2.  The desired temperature is controlled by rotating the 
temperature control knob. The knob has a numeric   
scale, where higher numbers correspond to higher temperature. 
  3.  On warmers equipped with an indicator light, the light will 
glow when the thermostat is calling for heat (i.e. the element is 
energized).
  4.  The 
TEMPERATURE CONTROL KNOB will rotate  approximately 
300º, and will reach a “stop” at both ends. 
The OFF position is marked.
NOTE: The dial position is an indication of the temperature setting. 
Actual temperature will vary depending upon the type of product and 
food consistency.
B.  MOUNTING
  1.  This top-mounted built-in warmers is equipped with   
WELLSLOKS, uniquely designed turnout tabs which help 
secure the warmer top ange to the countertop. 
  2.  See the Installation Instructions, supplied with the particular            
appliance, for details.
C.  DRAINS
  1.  Sufx “D” units (e.g. HSW-6D) have drains for each pan. 
Each drain will require an individual drain valve.
INDICATOR
LIGHT
TEMPERATURE
CONTROL
KNOB
IL2468
IL2469
WELLSLOKS
M011A 2M-308013 Owners Manual for Built-In Half Size Warmers
M011A 2M-308013 Owners Manual for Built-In Half Size Warmers