TROUBLESHOOTING
SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY
No power to warmer Circuit breaker off or tripped Reset circuit breaker
Warmer will not heat Temperature control not set Set control to desired temperature
Warmer trips circuit breaker
Wet insulation
Verify ange-to counter seal is sound, or
reseal with food-grade silicone sealant
Pan leaking or other internal damage
Contact your Authorized Wells Service
Agency for repairs
Internal damage
Contact your Authorized Wells Service
Agency for repairs
Warmer slow to heat
Mineral deposits on pan acting as a
insulator
Clean pan(s) with delime cleaner
Wired to wrong voltage
Verify supply voltage - must match voltage
on warmer nameplate
Drain-equipped unit will not hold
water
Drain valve not fully closed Check drain valve for debris and close fully
Drain valve damaged or pan(s) leaking
Contact your Authorized Wells Service
Agency for repairs
TROUBLESHOOTING SUGGESTIONS
10
There are no user-serviceable components in this appliance.
In all instances of damage or malfunction, contact your Authorized Wells Service Agency for repairs.
M011A 2M-308013 Owners Manual for Built-In Half Size Warmers