Operating instructions

VENTILATOR HOOD
HOOD SECTION - ANSUL® FIRE DETECTION SYSTEM
12
IMPORTANT:
All servicing of the fire
detection system to be
performed by an
authorized Ansul® agent
only.
1. Cooking appliance protected by a series detector by two 212ºF fusible
links at the inlet of the ventilator fan.
2. Fire suppression system may be activated by the manual pull station
on the front of the unit, or by a remote manual pull station if installed.
3. A microswitch in the Ansul® Automan assembly allows connection to
a building fire alarm system.
SV509 SvcManual WVOC-G136
ANSUL
®
PULL
HANDLE
TO ACTIVATE
FIRE SUPPRESSION
SYSTEM
IN CASE OF
FIRE
THREADED
THRU HOLE
BLIND
HOLE
CABLE SITS IN
GROOVE IN
PULLEY
HOOD ASSEMBLY
VIEWED FROM REAR
FUSE LINK
212ºF
FUSE LINK
212ºF
SERIES
DETECTOR
MANUAL
PULL STATION
PULLEY
ELBOW
MICROSWITCH