509 WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5707 fax: 775-689-5976 www.wellsbloomfield.com SUPPLEMENTAL SERVICE INSTRUCTIONS WVOC-G136 CONVECTION OVEN and GRIDDLE COOKTOP with VENTLESS HOOD SYSTEM IMPORTANT: WELLS BLOOMFIELD, LLC PROPRIETARY INFORMATION. DISSEMINATION OF THIS INFORMATION TO ANYONE OTHER THAN WELLS AUTHORIZED SERVICE AGENTS IS STRICTLY PROHIBITED. TECHNICAL CONTENT OF THIS MANUAL IS DESIGNED FOR USE BY QUALIFIED PROFESSIONAL TECHNICIANS ONLY.
PRECAUTIONS AND GENERAL INFORMATION GENERAL WARNING: RISK OF INJURY Installation procedures must be performed by a qualified technician with full knowledge of all applicable electrical and plumbing codes. Failure can result in personal injury and property damage. WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated electrical components must be performed by a qualified technician. Some procedures involve exposed live circuits.
GENERAL Precautions & General Information …………….………… Specifications ..……………………………...................….. Features & Operating Controls ……………………………. VENTILATOR HOOD SECTION Filter Arrangement .......................................................... Service Indicator Lights .…….......................................… Operational Notes ........................................................... Filter System ................................................................... Vacuum System ....................
FEATURES & OPERATING CONTROLS GENERAL 28 28 VENTILATOR CONTROL PANEL see pages 4 & 5 a15 28 1 56 53 19 16 18 a11 18 16 22 22 GRIDDLE CONTROL PANEL see pages 4 & 5 a10 IN CASE OF FIRE ANS UL ® PULL HANDLE TO ACTIVATE FIRE SUPPRESSION SYST EM 41 12 42 PO W ER O N COCKED H E A T ON O N HIG H O FF F AN FIRED LO W 43 TIM E a31 44 TEM P a6 40 U S E 10 A M P T Y P E A C F U S E O N LY 8 9 38 38 Fig.
VENTILATOR SECTION DESCRIPTION COMMENT 1. NAMEPLATE Lists Manufacturer, Model and Serial Number information. Also lists electrical specifications. a6. FIRE SUPPRESSION AGENT TANK (1.5 gal.) Container for Ansulex™ Low-pH liquid fire suppression liquid. 8. ADJUSTABLE (FRONT) LEG Allows the unit to be leveled. 9. RIGID (REAR) CASTER Allows the unit to be easily positioned by lifting the front of the unit slightly. a10.
FEATURES & OPERATING CONTROLS (continued) GENERAL V1 V2 V3 V4 V5 V6 Fig. 2 Ventilator Section Controls & Indicator Lights SV509 SvcManual WVOC-G136 Fig.
FEATURES & OPERATING CONTROLS (continued) DESCRIPTION COMMENT VENTILATOR SECTION CONTROLS V.01 V.02 V.03 POWER SWITCH POWER ON INDICATOR LIGHT CHECK FILTERS INDICATOR LIGHT Energizes blower motor. If, after 10 seconds, proper conditions are met, appliance is energized. GREEN. Glows when POWER switch is ON. AMBER. Glows if one or more filters are out of position. Check all filters and baffles for proper installation. V.04* REPLACE PREFILTER INDICATOR LIGHT AMBER.
HOOD SECTION - FILTER ARRANGEMENT FAN WALL OF UNIT FILTER PA CK SE AL FILTER PACK FILTER PA CK AIR FLOW VENTILATOR HOOD FILTER PA CK PO SITIO N SWITCH HOL DE R CLIP GRE ASE B AFFLE PO SITIO N SWITCH H OLDER CLIP CLIPS ONTO LEDGE PRE -FILTER AS SEMB LY GRE ASE BA FFL E GRE ASE TROUGH PRE -FILTER NOTE: AIR FL OW A RRO W PO INTS AWAY FROM INSTAL LER WHEN PRO PERLY INSTA LLE D FILTER HOOK R E TE R FILTER HOOK FILTER RAIL FILTER HANDLE FILTER FRAME NOTE: P RE-FILTER IS S ENSE D AS B EING IN POS
HOOD SECTION - SERVICE INDICATOR LIGHTS POWER SWITCH SV509 SvcManual WVOC-G136 INDICATOR LIGHT When lit, indicates that electrical power is available, (GREEN) VENTILATOR and that the power switch (V.01) is turned ON. POWER ON INDICATOR LIGHT (AMBER) CHECK FILTERS (POSITION) When lit, indicates that the BAFFLE, PRE-FILTER and/or FILTER PACK is not in its proper position, or that an interlock switch is out of adjustment.
HOOD SECTION - OPERATIONAL NOTES WARNING: FIRE AND HEALTH HAZARDS VENTILATOR HOOD DO NOT bypass or attempt to bypass the filter placement interlocks. Operating the appliance without filters properly in place will compromise the fire protection and air filtration capabilities of this unit. Serious personal injury and/or substantial property damage may result.
HOOD SECTION - OPERATIONAL NOTES (continued) FIRE DAMPER LABEL SHUTTER DAMPER SUPPORT FUSIBLE LINK 280ºF FIRE DAMPER INSTRUCTIONS 1. The FIRE DAMPER is accessible by removing the TOP PANEL The FIRE DAMPER sets in the DAMPER SUPPORT and may be removed by lifting straight up. SV509 SvcManual WVOC-G136 2. The FIRE DAMPER normally needs no maintenance. If it becomes heavily contaminated with dust and/or grease, it must be replaced. 3.
HOOD SECTION - FILTER SYSTEM HOOD ASSEMBLY (LOOKING UP) VENTILATOR HOOD FILTER PACK POSITION MONITOR GREASE BAFFLE POSITION MONITOR PRE-FILTER ASSEMBLY NOTE AIR FLOW ARROWS ON GREASE BAFFLE, PRE-FILTER AND FILTER PACK. INSTALL THESE COMPONENTS SUCH THAT ARROWS POINT TOWARD FAN FILTER PACK GREASE BAFFLE 1. The GREASE BAFFLE separates grease particles and water vapor from the air stream by the centrifugal force of the air moving through its inter-leaved baffle plates.
HOOD SECTION - VACUUM SYSTEM FAN PORT A VS4 VENTILATOR HOOD PORT A PORT B VS1 FAN PORT C PORT C PORT C VS3 PORT B PLENUM PORT (AFTER FILTER PACK) VS2 SV509 SvcManual WVOC-G136 VS2 FILTER PACK ALERT Will illuminate "REPLACE FILTER PACK" indicator if pressure drop across the filter pack exceeds setting. VS3 PRE-FILTER ALERT Will illuminate "REPLACE PRE-FILTER" indicator if pressure drop across the prefilter exceeds setting.
HOOD SECTION - ANSUL® FIRE DETECTION SYSTEM HOOD ASSEMBLY VIEWED FROM REAR SERIES DETECTOR VENTILATOR HOOD FUSE LINK 212ºF FUSE LINK 212ºF IN ANS UL CA FIRSE O E F BLIND HOLE PU HA NLDL LE FIRTO E AC SU TIV P SY PR ATE ST ES EM SIO ® N MANUAL PULL STATION THREADED THRU HOLE CABLE SITS IN GROOVE IN PULLEY PULLEY ELBOW IMPORTANT: All servicing of the fire detection system to be performed by an authorized Ansul® agent only. 1.
HOOD SECTION - ANSUL® FIRE SUPPRESSION SYSTEM HOOD ASSEMBLY VIEWED FROM REAR UNDER-HOOD NOZZLE ASSY VENTILATOR HOOD FLEX HOSE NOZZLE 1W APPLY SEALANT TAPE PLENUM NOZZLE ASSY NOZZLE 1W SEAL WITH TEFLON TAPE INS ID E OU TS IDE FIRE SUPPRESSION MEDIA TANK FIBER WASHER IS ALWAYS ON THE INSIDE CABINET WALL SV509 SvcManual WVOC-G136 SEAL WITH TEFLON TAPE TYPICAL BULKHEAD FITTING PRESSURE CARTRIDGE 1.
HOOD SECTION - TROUBLESHOOTING SUGGESTIONS SYMPTOM VENTILATOR HOOD Entire unit inoperative No lights glow No buzzer sounds Cooking appliance inoperative “POWER” light on hood ON. Vent fan working ok with no service Cooking appliance inoperative “POWER” light on hood ON. Vent fan working OK.
HOOD SECTION - TROUBLESHOOTING SUGGESTIONS (continued) POSSIBLE CAUSE Prefilter is at end of service life Vent fan working OK, but amber “REPLACE PREFILTER” light ON. Vacuum Switch VS3 damaged “REPLACE PREFILTER” light turns on some of the time. “REPLACE FILTER PACK” light ON. Replace prefilter Replace vacuum switch VS3 Pre-filter frame not hooked in position at top Hook metal pre-filterframe at top to prevent air blowing around filter Pre-filter position switch SW1 misadjusted or damaged.
OVEN SECTION - OPERATIONAL NOTES CAUTION: CONVECTION OVEN OPERATING INSTRUCTIONS HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. C.03 C.04 C.01 C.02 CAUTION: C.05 A SHOCK HAZARD C.05 DO NOT splash or pour water onto control panel or wiring. C.05 B C.06 C.07 C.08 C.09 C.10 C.11 NOTE: Damage caused by moisture leaking into the electronic controller is NOT covered by warranty.
OVEN SECTION - OPERATIONAL NOTES (continued) B. PROGRAM COOK MODE 1. Five (5) programmable keys (C.10) are provided for presetting frequently used time / temperature combinations. To set the program: a. Press and hold the appropriate PGM key. b. While holding the PGM key, turn the TIME and TEMP knobs until the desired time and temperature is displayed on the readout. c. Release the PGM key to store the displayed time and temp in memory. 2.
OVEN SECTION - SERVICING INSTRUCTIONS DANGER CONTROLLER ELECTRIC SHOCK HAZARD “HEAT” INDICATOR “POWER” INDICATOR DRIP SHIELD FAN H IGH/LOW SWITCH ON/OFF/FAN SWITCH CONTROLLER SILICONE BOOT CONTROL SHAFT GASKET CONTROL KNOB DO NOT SPRAY WATER ON OR AROUND ELECTRICAL EQUIPMENT DO NOT WASH FLOOR NEAR ELECTRICAL EQUIPMENT WITH WATER SPRAY OVEN ELECTRICAL HI-LIMIT THERMOSTAT ALTERNATE COMPONENTS HEATING ELEMENTS WARNING: SHOCK HAZARD TEMP PROBE TEMP PROBE OVEN All servicing requiring access to no
OVEN SECTION REPLACE- SERVICING SPRING FOR INSTRUCTIONS FRYHEAD SUPPORT (continued) ROD CAUTION: DRIP SHIELD HOT SURFACE Exposed surfaces can be hot to the touch and may cause burns. GASKETS CAUTION: SWITCH BOOTS SHOCK HAZARD Disconnect power before servicing the controller. REPLACE CONVECTION OVEN CONTROLLER 1. Disconnect unit from electric power and allow to cool. 2. Remove time and temperature control knobs. Knobs pull straight off shafts. 3. Note and mark wiring connected to rear of controller.
OVEN SECTION - SERVICING INSTRUCTIONS (continued) CAUTION: TEST BLOWER FAN MOTOR HOT SURFACE A. IF motor does not run with power switch in ON or FAN position. Attempt to start motor by spinning blower wheel clockwise. IF motor starts, replace capacitor (p/n 69823). IF motor does not start, check motor, switch and wiring. IF fan is hard to turn, check motor mounting to be sure fan is not rubbing, otherwise replace motor (p/n 63932). B. IF motor runs in power switch FAN position, but not in ON position.
OVEN SECTION REPLACE- SERVICING SPRING FOR INSTRUCTIONS FRYHEAD SUPPORT (continued) ROD SV509 SvcManual WVOC-G136 REPLACE ELEMENT 1. Remove right side panel, racks, rack supports and fan baffle. 2. Note position of wires on elements. Disconnect wires to element(s) being replaced. 3. Loosen nuts holding element clamps to cabinet. Disassemble element clamps. 4. Work elements out of clamps until element being replaced can be removed. 5. Insert new element terminals through insulation and cover plates. 6.
OVEN SECTION - SERVICING INSTRUCTIONS (continued) CAUTION: REPLACE TEMPERATURE PROBE HOT SURFACE • Exposed surfaces can be hot to the touch and may cause burns. CAUTION: SHOCK HAZARD Multiple live electrical circuits are present inside the control section of the cabinet. Disconnect power before removing the side panel. TEMP PROBE OVEN HI-LIMIT THERMO APPLY SEALANT OLD-STYLE 1. Remove racks, rack support and fan baffle. Remove oven right side panel. 2.
OVEN SECTION REPLACE- SERVICING SPRING FOR INSTRUCTIONS FRYHEAD SUPPORT (continued) ROD CAUTION: RELAY AND CONTACTOR REPLACEMENT Per Federal environmental regulations, mercury-bearing devices may no longer be included in new-manufacture appliances. For Wells Bloomfield equipment, this applies mainly to mercury-wetted-contact relays. In addition, the E-Safe I electronic relay has been phased out in favor of the E-Safe II relay.
OVEN SECTION - SERVICING INSTRUCTIONS (continued) CAUTION: BURN HAZARD Allow appliance to cool completely before adjusting. HINGE ADJUSTMENT PRECAUTIONS: None FREQUENCY: Monthly, at a Minimum; or, As Needed TOOLS: Phillips (+) Screwdriver 7/16" Nut Driver 7/8" and 1-1/8" Wrenches THE FOLLOWING PROCEDURE IS TO BE PERFORMED BY QUALIFIED PERSONNEL ONLY CHECK ALIGNMENT 1. Remove bottom panel to access pivot. EQUAL CLEARANCES OVEN BOTTOM PANEL 2.
OVENREPLACE SECTIONSPRING - TROUBLESHOOTING FOR FRYHEAD SUPPORT SUGGESTIONS ROD No power to appliance SV509 SvcManual WVOC-G136 Oven will not heat Fan does not run Door pops open during cook cycle ERROR CODES POSSIBLE CAUSE SUGGESTED REMEDY Circuit breaker off or tripped Reset circuit breaker Power cord unplugged or damaged Check power cord Plug in or repair as required Hood section not "ON" Verify that Hood Power Switch is "ON". If "SERVICE REQUIRED" indicator is lit, rectify filter problem.
GRIDDLE SECTION - OPERATIONAL NOTES REMOVABLE SPLASH GUARD G-136 GRIDDLE UNIT THERMOSTAT (typical) CONTROL PANEL CONTROL KNOB (typical) IN GREASE DRAWER CA SE FIR OF E AN SU L PU HA LL ND LE CAUTION: 1. The main cooking appliance is a Wells G-136 Griddle. BURN HAZARD 2. The griddle has two individually controllable sections. Control is via capillary and bulb thermostat with DPST switch. Griddle surfaces are very hot during operation. Allow unit to cool before performing any service. 3.
GRIDDLE SECTION - SERVICING INSTRUCTIONS REPLACE THERMOSTAT WARNING 1. Disconnect unit from electric power and allow to cool before servicing. HOT SURFACES 2. Withdraw grease tray from unit. Empty grease into an appropriate container. 3. Remove six screws from recessed lip of control panel. Remove control panel from unit. Griddle surface can be VERY HOT and may cause severe burns on contact. CAUTION: SHOCK HAZARD 4. Remove griddle control knob by pulling straight off. 5.
GRIDDLE SECTION - SERVICING INSTRUCTIONS (continued) WARNING REPLACE HEATING ELEMENT(S) HOT SURFACES Griddle surface can be VERY HOT and may cause severe burns on contact. CAUTION: SHOCK HAZARD TT OM OF TO PP AN EL Disconnect electric power before servicing. 1. Disconnect unit from electric power and allow to cool before servicing. 2. Withdraw grease tray from unit. Empty grease into an appropriate container. 3. Remove six screws from recessed lip of control panel.
GRIDDLE SECTION - ELEMENT CLAMPING DIAGRAM 520 520 51969 51969 54 54 52028 52028 53474 52028 53474 52028 51969 FRONT 54 54 51969 53474 53474 520 51969 520 51969 51968 51968 51968 51968 51968 51972 53474 51972 53474 51969 51968 51969 ELEMENT RETAINER STUD LOCATION 50496 HEATING ELEMENT 208/240V DESCRIPTION POSSIBLE PROBLEM SUGGESTED REMEDY Griddle will not heat Hood section not "ON" Verify that Hood Power Switch is "ON".
EXPLODED VIEWS HOOD CABINET COMPONENTS INTERNAL BRACKETS FIRE DAMPER ASSY 280ºF (ref.
FITTING, 1/2” CONDUIT STRAIGHT 57748 EXPLODED VIEWS HOOD ELECTRICAL & VACUUM COMPONENTS ASSY, BLOWER 240V 502584 VACUUM SWITCH #4 502593 VACUUM SWITCH #1 502590 VACUUM SWITCH #3 502592 ASSY, VAC TUBE MANIFOLD 502588 VACUUM SWITCH #2 502591 ref Ansul® 77284 ref Ansul® 77284 SWITCH, POWER 8528-40 SWITCH, FILTER INTERLOCK 500407 (2 pl) BUZZER, 240V 64834 LIGHT, INDICATOR GREEN 240V 55697 LIGHT, INDICATOR AMBER 240V 50516 (3 pl) ON TO FH D HOUSING, LIGHT SOCKET 505098 BULB, APPLIANCE 230V 100
CONVECTION OVEN CABINET SUPPORT, OVEN RACK 21375 ET CLIP, RACK SUPPORT 63889 BIN CA PIN, HINGE 505610 OR DO DOOR STRIKER 505616 DOOR LATCH 505615 OVEN RACK 21376 ASSEMBLY, DOOR COMPLETE 504444 GUARD, PROX. SWITCH 65647 DOOR BRACKET PROX.
ELEMENT, INNER 63872 (208V) 63783 (240V ELEMENT OUTER 63800 (208V) 63833 (240V) CONTACTOR 208/240V 3ø 50a 502789 COVER, GASKET INNER 63836 BACK OF UNIT RELAY, BLDG FIRE ALARM 64514 THERMO, HI-LIMIT 65180 TERMINAL BLOCK FIRE ALARM 53068 JUMPER, FLAME SENSOR 54005 FUSEHOLDER HPA-EE 10A 54769 PROBE, TEMP OC-1 504712 FUSE SC-10 54871 (pk 4) GASKET, ELEMENT 63834 STRAIN RELIEF 1-1/4 NPT 504420 WHEEL, BLOWER 63797 RELAY, E-SAFE (208/240V) 506967 SWITCH, PROXIMITY 65239 BRACKET, PROX.
GRIDDLE ELEMENTS EXPLODED VIEWS INSULATION PAD 57407 (pk 2'x4') COVER, GREASE DRAWER 51995 NUT, 1/4-20 HEX Ni 51253 (pk 100) CLAMP, THERMO BULB 52028 CLIP, TIE-DOWN INSULATION 53474 (pk 12) TUBE, THERMO BULB 18" 51972 CLAMP, ELEMENT END 51969 CLAMP, ELEMENT CENTER 51968 NUT, 10-32 HEX 55313 JUMPER, ELEMENT SHORT 52054 (pk 10) T ON FR GRIDDLE (REF.
SPLASHGUARD LEFT 55781 SPLASHGUARD G-13 COMPLETE ASSY 20632 SPLASHGUARD, REAR 54437 SPLASHGUARD, RIGHT 55780 GRIDDLE PLATE ASSEMBLY 51476 SEALANT, G-136 5/16” x 96” 53308 SLEEVING, 5/16” 52040 (6” rl) (2 reqd) SHIELD, THERMO 51974 (2 reqd) OUTLET BOX 51997 TERMINAL BLOCK 50131 THERMO, CONTROL 50257 (2 reqd) SCREW, 6-32x3/16 51718 (pk10) BUSHING, HEYCO 7/8” 51040 (2 reqd) KNOB 50259 (2 reqd) LIGHT, SIGNAL AMBER 208/240V 50516 480V 60436 NUT, HEX ALUMINUM 8-32 x 7/8” 61974 (pk 10) COVER, OUTLET BOX 520
PARTS BREAKDOWN for ANSUL® COMPONENTS EXPLODED VIEWS FOR USE ONLY BY AUTHORIZED ANSUL© SERVICE PERSONNEL Refer to Ansul© part no. 418078-05 R-102 Restaurant Fire Suppression System Design, Installation, Recharge and Maintenance ref. NOZZLE 290 ANSUL© p/n 419342 ref. NOZZLE 1W ANSUL© p/n 419336 ref. ADAPTER, QUICK-SEAL 3/8” ANSUL© p/n 77284 FUSIBLE LINK MODEL K 212ºF 503037 ASSY, PULL STATION ANSUL© 501389 F TO IT UN ON FR ref.
SV509 SvcManual WVOC-G136 EXPLODED VIEWS NOTES 37
WIRING SCHEMATIC HOOD SECTION G L1 L2 L3 CAC-1 CAC-2 CAC-3 WIRING SERVICE REQUIRED INDICATOR PS1-1 FS1(NC) CHECK FILTER INDICATOR SW1 VS4 VS1 SW2 PS1-2 COIL TB1 JUMPER COOKING APPLIANCE CONTACTOR BLOWER MOTOR POWER ON INDICATOR VS3 REPLACE PREFILTER INDICATOR VS2 REPLACE FILTER PACK INDICATOR FS1(NO) ZZZ ANSUL® SYSTEM BUZZER TO BLDG FIRE ALARM SYSTEM COIL FIRE ALARM RELAY 38 WVOC-G136 HOOD SECTION WIRING SCHEMATIC LEGEND CAC = COOKING APPLIANCE CONTACTOR FS- = ANSUL® FIRE ALARM SWITCH
WIRING DIAGRAM HOOD SECTION 16 EXTERNAL CONTROL TERMINAL BLOCK 1 EXTERNAL SHUTDOWN CONTROL 13 JUMPER 2 1 3 21 22 6 10 14 15 BLACK WHITE HOOD LIGHT 7 12 9 VACUUM SWITCH VS4 (AIRFLOW) POWER CORD 4 L1 L2 L3 T1 T2 T3 24 NO RED ANSUL® SYSTEM FIRE SWITCH C GROUND BLACK NO CONTACTOR 5 2 208/240VAC 75 AMPS NC 23 BLOWER MOTOR GREASE BAFFLE POSITION SW 19 C VACUUM SWITCH FILTER PACK VS1 (PREFILTER) POSITION SW 17 1 NO 2 18 25 NO 3 COOKING APPLIANCE NO 26 3 5 C 27 2
WIRING SCHEMATIC OVEN SECTION FROM COOKING APPLIANCE CONTACTOR L1 L2 L3 G WIRING HEATING INDICATOR HLR-2 HEATING ELEMENT ESR-1 HLR-1 ESR-3 HLR-3 HEATING ELEMENT ESR-2 COOLING FAN C PS-1 ON 10A OFF HI-LIMIT THERMO FAN OVEN CONTROLLER DR-1 E FUSE PS-2 ON OFF DR-2 FAN DOOR PROX. SW.
WIRING DIAGRAM OVEN SECTION OVEN CONTROLLER 18 27 35 28 E FROM COOKING APPLIANCE CONTACTOR ON-OFF-FAN MAIN SWITCH 19 TEMP SENSOR 35 33 31 37 39 10A 41 29 26 10A L2 16 L3 4 6 1 3 13 21 DOOR PROX.
WIRING SCHEMATIC GRIDDLE SECTION FROM COOKING APPLIANCE CONTACTOR G L1 L2 L3 WIRING T1-2 T1-1 T T GRIDDLE HEATING ELEMENT (RIGHT) HEATING INDICATOR T2-2 T2-1 T GRIDDLE HEATING ELEMENT (LEFT) T HEATING INDICATOR WVG-136(RW) GRIDDLE SECTION WIRING SCHEMATIC LEGEND T1, T2 = GRIDDLE THERMOSTAT SV509 SvcManual WVOC-G136 42
WIRING DIAGRAM GRIDDLE SECTION RIGHT HEATING ELEMENT PAIR 240VAC 4500 WATTS TOTAL 3 WIRING LEFT HEATING ELEMENT PAIR 240VAC 4500 WATTS TOTAL 2 R R PE PE M JU M JU 6 L1 7 L2 4 5 FROM COOKING APPLIANCE CONTACTOR L3 R R PE PE M M JU JU 1 9 8 T 9 9 T HEATING INDICATOR CONTROL THERMOSTAT SV509 SvcManual WVOC-G136 CONTROL THERMOSTAT 8 43 HEATING INDICATOR WIRING DIAGRAM WVOC-G136 GRIDDLE SECTION from p/n 305931 issue B
MSDS - ANSULEX™ Low pH FIRE SUPPRESSION MEDIA DOCUMENTATION SV509 SvcManual WVOC-G136 44
SV509 SvcManual WVOC-G136 DOCUMENTATION MSDS - ANSULEX™ Low pH FIRE SUPPRESSION MEDIA 45
DOCUMENTATION SV509 SvcManual WVOC-G136 46 WELLS BLOOMFIELD, LLC
47 Max interval: 12 months Replace fire damper fusible link: rated @ 280ºF Replace two (2) fire suppression links at cooking appliance: each link is rated @ 212ºF SV509 SvcManual WVOC-G136 DOCUMENTATION WELLS BLOOMFIELD, LLC
IMPORTANT: WELLS BLOOMFIELD, LLC PROPRIETARY INFORMATION. DISSEMINATION OF THIS INFORMATION TO ANYONE OTHER THAN WELLS AUTHORIZED SERVICE AGENTS IS STRICTLY PROHIBITED. TECHNICAL CONTENT OF THIS MANUAL IS DESIGNED FOR USE BY QUALIFIED PROFESSIONAL TECHNICIANS ONLY. Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association WELLS BLOOMFIELD, LLC 2 ERIK CIRCLE, P. O. Box 280 Verdi, NV 89439 telephone: 775-689-5707 fax: 775-689-5976 www.wellsbloomfield.