Installation Guide

For customer support,please call WELLFOR (+1)206-809-0093 or Email us at service@wellfor.com
PAGE 5
1.Connect valve body to water supplies using the proper fitting(copper tubing, iron pipe or Pex).
If either of the two outlet ports is to be unused, seal the port with a pipe plug.
Note: (1) is the cold inlet port and (2) is the hot inlet port.
2. For copper pipe soldering joint, you need to remove the plastic covers(3) and (4) and valve
cartridge from the valve body first. Avoiding soldering at high temperatures. Component of
the rough could become damaged.
3. Remove bonnet nut and thread nut from the valve body.
(1)
(3)
(4)
(2)
Warning: soldering joint have high
tempeture,do not touch hot surfaces.