Datasheet

43
EN
Parameter menu
Floating switching output 2 Menu access Station parameters
Floating switching output 2 is located at the COM 2 port.
Option Description
OFF (factory setting)
CH 1 Tool channel 1 controls the switching output
CH 1+2 Tool channel 1 + 2 controls the switching output
CH 1+2+3 Tool channel 1 + 2 + 3 controls the switching output
Notice
If the robot is at working temperature, the display will show – ok –.
Technical Data
Repair station WXR 3
Dimensions L x W x H 273 x 235 x 102 mm
(10,75 x 9,25 x 4,02 inch)
Weight ca. 6,7 kg
Mains supply voltage 230 V, 50 Hz T0053500699
120 V, 60 Hz WXR 3
100 V 50/60 Hz T0053500199
Power consumption 420 W (600 W)
Safety class I, antistatic housing
III, Soldering tool
Fuse Overcurrent release 230 V; 2,0 A
120 V; 4,0 A
Temperature range Celsius: 100 - 450°C (550°C)
Fahrenheit: 200 - 850°F (999°F)
Controllable temperature range is tool-dependent
Temperature accuracy ± 9 °C (± 17 °F) Tool dependent (WXHAP ±30 °C / ±80 °F)
Temperature stability ± 2 °C (± 4 °F)
Equipotential bonding Via 3.5 mm pawl socket on back of unit
Display 240 x 88 dots / Backlighting
USB port The control unit comes with a front-side USB port for installing rmware
updates, conguration and monitoring.
Pump (Intermittent mode
(30/30) s)
Max. vacuum 0,7 bar
Max. delivery rate 18 l/min
Max. hot air 15 l/min
Additional vacuum pump Max. vacuum0,5 bar
Max. delivery rate 1,7 l/min