Parameter menu
Pressure gauge threshold Menu access Station parameters
This function can be used to dene the mainte-
nance interval of the desoldering tool. This is done
by setting the value in mbar at which the electric
pressure gauge issues a warning signal when the
intake system is contaminated (LED of the vacuum
pump switches from green to red). The set value is
dependent on the suction nozzles used.
Adjustable -400 mbar to -800 mbar
factory setting -600 mbar
1. The system (tips and lter) must be free.
2. Select the menu item „Pressure gauge
threshold“ in the menu.
3. Set the „Pressure gauge threshold“ pressure
value with the UP or DOWN button. The status
LED switches back and forth between red and
green. Use the UP button to increase vacuum
by 50 to 80 mbar, then pinch the vacuum tube
and check whether the LED switches from
green to red.
4. Adopting the set change.
Interface COM 1 / 2 Menu access Station parameters
Option Description
RS232 Serial communication with PC or other compatible Weller devices (factory setting).
Air The COM 1 port is congured as a foot switch input for activating the air ow.
Vac The COM 1 port is congured as a foot switch input for activating the vacuum.
PickUp The COM 1 port is congured as a foot switch input for activating the PickUp vacuum.
Stop&Go The COM 1 port is used to drive an optional optotransmitter so that a KHE-P control
unit can be activated via an optical bre.
The output is activated when a tool is used. In addition, the oating switched output is
closed. The output is off in the Standby, Auto Off or Off positions, or if no tool is inserted.
Floating switching output 1 Menu access Station parameters
Floating switching output 1 is located at the COM 1 port.
Option Description
OFF (factory setting)
ZeroSmog The oating switching output is closed when a tool is in use. Selected Zero Smog
extraction systems can be connected using an optional adaptor (WX HUB). The rear
RS 232 port remains functional.
Switching output is open in the Standby, Auto Off or Off positions, or if no tool is inser-
ted.
Notice
If the COM 1 port is also congured for „Stop&Go“ use, the „Filter full“
message is evaluated by the WX HUB and, where applicable, a
message appears on the display .