Datasheet

41
EN
Parameter menu
Password (lock function) Menu access Station parameters
After switching the lock function on, only the xed
temperature keys can be operated on the solde-
ring station. All other settings are disabled until the
repair station is unlocked again.
Notice
If you want only one temperature value to be
selectable, the control keys xed temperature
keys) must be set to the same temperature value.
Locking the soldering station
Set the desired three-digit locking code (between
001 and 999) using the UP / DOWN buttons.
Conrm the code with the Enter key.
The lock is active (the display shows a lock
symbol).
Unlocking the soldering station
1. Call up the parameter menu. If the lock function
is active, the password menu item opens
automatically. Three stars (***) are shown on
the display.
2. Set the three-digit locking code using the UP /
DOWN buttons.
3. Conrm the code with the Enter key.
Forgotten code?
Please contact our Customer
Service: technical-service@
weller-tools.com
Single-channel display Menu access Station parameters
To obtain more straightforward readings, the
display mode from can switched from 3-channel
display to 1-channel display.
If single-channel display is selected, the device
does not reset automatically to 3-channel display
after setting the temperature of a tool channel.
The display mode can be reset using ┌ 2 ┐.
Option Description
OFF Automatic reset to 3-channel display
(factory setting)
ON No automatic reset to 3-channel
display
Vacuum pre-feed Menu access Station parameters
In order to prevent the pump from starting pre-
maturely or to ensure a dened soldering-joint
preheating time, it is possible to set an ON delay.
Option Description
0 sec OFF: vacuum pre-feed function is
OFF (factory setting)
1-10 sec ON: vacuum pre-feed time, indivi-
dually
Vacuum run-on Menu access Station parameters
To prevent the desoldering iron from becoming
clogged, it is possible to set a vacuum run-on time.
Option Description
0 sec OFF: vacuum run-on function is OFF
(factory setting)
1-10 sec ON: vacuum run-on time, individually
adjustable