Datasheet

Safety Data Sheet according to
Regulation (EC) No. 1907/2006
(REACH)
Weller Tip -Tinner -Activator
Print date 28.01.2014
Revision date 28.01.2014
Version 4.2
4.2 Most important symptoms and effects, both acute and delayed
No data available
4.3 Indication of any immediate medical attention and special treatment needed
No data available
SECTION 5: Firefighting measures
5.1 Extinguishing media
Suitable extinguishing media
Extinguishing powder. Dry sand. D powder.
Unsuitable extinguishing media
High power water jet. Carbon dioxide.
5.2 Special hazards arising from the substance or mixture
No data available
5.3 Advice for firefighters
Special protective equipment for firefighters:
In case of fire: Wear self-contained breathing apparatus.
SECTION 6: Accidental release measures
6.1 Personal precautions, protective equipment and emergency procedures
For non-emergency personnel
Personal precautions
See protective measures under point 7 and 8.
6.2 Environmental precautions
Do not empty into drains or the aquatic environment.
6.3 Methods and material for containment and cleaning up
No data available
6.4 Reference to other sections
No data available
SECTION 7: Handling and storage
7.1 Precautions for safe handling
Protective measures
Advices on safe handling
If local exhaust ventilation is not possible or not sufficient, the entire working area should be ventilated by technical means.
Measures to prevent aerosol and dust generation
Vapours / aerosols should be extracted by suction directly at point of origin.
7.2 Conditions for safe storage, including any incompatibilities
Hints on joint storage
Storage class
Non-combustible solids
TRGS-510 Lagerklasse 13
Further information on storage conditions
Keep in a cool, well-ventilated place.
7.3 Specific end use(s)
No data available
SECTION 8: Exposure controls/personal protection
8.1 Control parameters
Occupational exposure limit values
CAS No. Substance name LTV STV remark
7440-31-5 Tin compounds, inorganic, except SnH4 2 mg/m³ 4 mg/m³
Great Britain (UK)
LTV = long-term occupational exposure limit value
STV = short-term occupational exposure limit value
8.2 Exposure controls
Appropriate engineering controls
Technical measures to prevent exposure
Technical measures and the application of adequate working methods take priority over the use of personal protection equipment.
Page 3/6