SDS
Table Of Contents
- 1.2. Intended Use of the Product
- 1.4. Emergency Telephone Number
- 2.1. Classification of the Substance or Mixture
- GHS-US/CA Classification
- GHS-US/CA Labeling
- 2.3. Other Hazards
- 2.4. Unknown Acute Toxicity (GHS-US/CA)
- 3.1. Substance
- 3.2. Mixture
- 4.2. Most Important Symptoms and Effects Both Acute and Delayed
- 4.3. Indication of Any Immediate Medical Attention and Special Treatment Needed
- 5.1. Extinguishing Media
- 5.2. Special Hazards Arising From the Substance or Mixture
- 5.3. Advice for Firefighters
- 6.1. Personal Precautions, Protective Equipment and Emergency Procedures
- 6.1.1. For Non-Emergency Personnel
- 6.2. Environmental Precautions
- 6.3. Methods and Materials for Containment and Cleaning Up
- 6.4. Reference to Other Sections
- 7.1. Precautions for Safe Handling
- 7.3. Specific End Use(s)
- 8.1. Control Parameters
- 12.1. Toxicity
- 12.2. Persistence and Degradability
- 12.3. Bioaccumulative Potential
- 12.4. Mobility in Soil
- 15.1. US Federal Regulations
- 15.2. US State Regulations
- 15.3. Canadian Regulations
WSW SAC L0 / WSW SAC M1 - Solder Wire lead free Sn3.0Ag0.5Cu Flux L0/M1
Safety Data Sheet
According To Federal Register / Vol. 77, No. 58 / Monday, March 26, 2012 / Rules And Regulations And According To The Hazardous Products Regulation (February 11, 2015).
09/15/2021
EN (English US)
7/9
Germ Cell Mutagenicity: Not classified (Based on available data, the classification criteria are not met)
Carcinogenicity: Not classified (Based on available data, the classification criteria are not met)
Specific Target Organ Toxicity (Repeated Exposure): Not classified (Based on available data, the classification criteria are not met)
Reproductive Toxicity: Not classified (Based on available data, the classification criteria are not met)
Specific Target Organ Toxicity (Single Exposure): Not classified (Based on available data, the classification criteria are not met)
Aspiration Hazard: Not classified (Based on available data, the classification criteria are not met)
Symptoms/Injuries After Inhalation: Exposure may produce cough, mucous secretions, shortness of breath, chest tightness or other
symptoms indicative of an allergic/sensitization reaction. Inhalation of fumes may cause metal fume fever.
Symptoms/Injuries After Skin Contact: May cause an allergic skin reaction. Contact with hot, molten metal will cause thermal burns.
Symptoms/Injuries After Eye Contact: Contact may cause irritation due to mechanical abrasion.
Symptoms/Injuries After Ingestion: Ingestion may cause adverse effects.
Chronic Symptoms: Inhalation of fumes may cause metal fume fever.
11.2. Information on Toxicological Effects - Ingredient(s)
LD50 and LC50 Data:
Rosin (8050-09-7)
LD50 Oral Rat
7600 mg/kg
LD50 Dermal Rabbit
> 2500 mg/kg
LC50 Inhalation Rat
110 mg/m³
LC50 Inhalation Rat
2.3 mg/l/4h
Tin (7440-31-5)
LD50 Dermal Rat
> 2000 mg/kg
LC50 Inhalation Rat
> 4.75 mg/l/4h
Copper (7440-50-8)
LC50 Inhalation Rat
> 5.11 mg/l/4h
Silver (7440-22-4)
LD50 Oral Rat
> 5000 mg/kg
LD50 Dermal Rat
> 2000 mg/kg
LC50 Inhalation Rat
> 5.16 mg/l/4h
SECTION 12: ECOLOGICAL INFORMATION
12.1. Toxicity
Ecology - General: Harmful to aquatic life with long lasting effects.
Rosin (8050-09-7)
EC50 - Crustacea [1]
3.8 – 5.4 mg/l (Exposure time: 48 h - Species: Daphnia magna)
Silver (7440-22-4)
LC50 Fish 1
0.00155 – 0.00293 mg/l (Exposure time: 96 h - Species: Pimephales promelas [static])
EC50 - Crustacea [1]
0.00024 mg/l (Exposure time: 48 h - Species: Daphnia magna [Static])
LC50 Fish 2
0.0062 mg/l (Exposure time: 96 h - Species: Oncorhynchus mykiss [flow-through])
12.2. Persistence and Degradability
WSW SAC L0 / WSW SAC M1 - Solder Wire lead free Sn3.0Ag0.5Cu Flux L0/M1
Persistence and Degradability
May cause long-term adverse effects in the environment.
Copper (7440-50-8)
Persistence and Degradability
Not readily biodegradable.
12.3. Bioaccumulative Potential
WSW SAC L0 / WSW SAC M1 - Solder Wire lead free Sn3.0Ag0.5Cu Flux L0/M1
Bioaccumulative Potential
Not established.
12.4. Mobility in Soil
WSW SAC L0 / WSW SAC M1 - Solder Wire lead free Sn3.0Ag0.5Cu Flux L0/M1
Ecology - Soil
No data available.