Datasheet
MGS Eng 2006-10
HiGH-AirFLOW FuMe extrActiOn
Bravoform 2006
Technical data MG75 MG95 MG100s MG350s
Max suction capacity, m
3
/h (CFM) 70 (41,2) 100 (58,8) 100 (58,8) 310 (182,3)
Sound level dB(A) at 1 m 38-49 38-50 <52 <54
HEPA class micro lter - separation degree, DOP% >99,97 >99,97 >99,97 >99,97
Gas lter - chemisorbtion - separation degree, % >95 >95 >95 >95
Power, W 100 100 100 300
Voltage, V 100/250 100/250 100/250 115/230
Remote control yes yes no yes
Height, mm (in) 640 (25,2) 640 (25,2) 640 (25,2) 1000 (39,4)
Width, mm (in) 465 (18,3) 465 (18,3) 460 (18,1) 450 (17,7)
Depth, mm (in) 220 (8,7) 220 (8,7) 210 (8,3) -
Weight, kg (ld) 18 (40) 21 (46) 21 (46) 45 (99)
Warranty, except for lters, years 2 2 2 2
Filter concept!
Unique lter system built in three steps:
HEPA class micro lter for particle seperation
Gas lter for both low and high weight gas molecules
Dust lter
The lters are designed to achieve maximum
performance and are tested and documented
by a third party.
MG lter design with veried function makes the
lter systems unique on the market.
Filter exchange in MG lter systems are made easy.
The HEPA lter and gas lter are integrated in one
unit to ensure the best function and quick and
easy lter exchange.
For applications with a lot of dust or particles it
is recommended to use an extra pre-lter. This
will increase the lifetime of the main lter.
Max. media temperature 50°C (122°F)
Filtronic AB is striving to create a better workbench environment by developing and producing particle and gas lter
systems of very high quality. The lter systems are easy to use and install, have a low noise level and a guaranteed
function. Read more about us and our products at www.ltronic.se.
FILTRONIC AB
Box 2284, SE-531 02 Lidköping, Sweden
Tel: +46 510 208 10, Fax: +46 510 201 40
E-mail: ofce@ltronic.se www.ltronic.se
For better workbench environment!