Datasheet
FTS Eng 2006-10
HiGH-VACUUM FUME ExTrACTion
Bravoform 2006
Technical data FT11 FT12 FT12-PF FE3000 FC15 FC50
Bench top Bench top Bench top Bench top Central Central
system system
Max connected soldering irons 1 2 2 2 18 50
Height/diameter (height/width FE3000), cm (in) 20/12 (7,9/4,7) 20/12 (7,9/4,7) 24,5/12 (9,6/4,7) 33,5/28 (13,2/11) 38,5/92 (15,2/36,2) 38,5/92 (15,2/36,2)
Weight, kg (lb) 1.5 (3,3) 1.5 (3,3) 1.5 (3,3) 6.7 (14,8) 30 (66,2) 30 (66,2)
Sound level dB(A) at 1 meter 37 37 37 42 53 56
Air consumption, L/min 12 12 13 - - -
Air consumption, NL/min 12-40 12-40 12-40 - - -
Suction capacity, L/min 20-30 20-50 20-50 >50 1200 2100
Working pressure, bar (PSI) 3.5-7 (50-100) 3.5-7 (50-100) 3,5-7 (50-100) - - -
Voltage, V - - - 115/240 240 240
Power, W - - - 45 400 1200
Micro lter separation degree, DOP% >99.99 >99.99 >99.99 >99.99 >99.99 >99.99
Gas lter/chemisorbtion/separation degree, % >99 >99 >99 >99 >99 >99
Filter concept!
Unique lter concept built in four steps:
Pre-lter for dirt and dust (FT and FE units)
Micro lter (HEPA) for small particles
Gas lter for both high and low weight gas molecules
Dust lter
The lters are designed to achieve maximum
performance and are tested and documented
by a third party.
Our lter design with veried function makes the
lter systems unique on the market.
The main lter has an integrated particle lter
(HEPA) and gas- and dust lter for best function
and easy lter exchange. The pre-lter protects
the main lter and is changed separately for longer
lter lifetime.
Filtronic AB is striving to create a better workbench environment by developing and producing particle and gas lter
systems of very high quality. The lter systems are easy to use and install, have a low noise level and a guaranteed
function. Read more about us and our products at www.ltronic.se.
Max. media temperature 50°C (122°F)
FiLTroniC AB
Box 2284, SE-531 02 Lidköping, Sweden
Tel: +46 510 208 10, Fax: +46 510 201 40
E-mail: ofce@ltronic.se www.ltronic.se