Datasheet

FTS Eng 2006-10
HiGH-VACUUM FUME ExTrACTion
Bravoform 2006
Technical data FT11 FT12 FT12-PF FE3000 FC15 FC50
Bench top Bench top Bench top Bench top Central Central
system system
Max connected soldering irons 1 2 2 2 18 50
Height/diameter (height/width FE3000), cm (in) 20/12 (7,9/4,7) 20/12 (7,9/4,7) 24,5/12 (9,6/4,7) 33,5/28 (13,2/11) 38,5/92 (15,2/36,2) 38,5/92 (15,2/36,2)
Weight, kg (lb) 1.5 (3,3) 1.5 (3,3) 1.5 (3,3) 6.7 (14,8) 30 (66,2) 30 (66,2)
Sound level dB(A) at 1 meter 37 37 37 42 53 56
Air consumption, L/min 12 12 13 - - -
Air consumption, NL/min 12-40 12-40 12-40 - - -
Suction capacity, L/min 20-30 20-50 20-50 >50 1200 2100
Working pressure, bar (PSI) 3.5-7 (50-100) 3.5-7 (50-100) 3,5-7 (50-100) - - -
Voltage, V - - - 115/240 240 240
Power, W - - - 45 400 1200
Micro lter separation degree, DOP% >99.99 >99.99 >99.99 >99.99 >99.99 >99.99
Gaslter/chemisorbtion/separation degree, % >99 >99 >99 >99 >99 >99
Filter concept!
Unique lter concept built in four steps:
Pre-lter for dirt and dust (FT and FE units)
Micro lter (HEPA) for small particles
Gas lter for both high and low weight gas molecules
Dust lter
The lters are designed to achieve maximum
performance and are tested and documented
by a third party.
Our lter design with veried function makes the
lter systems unique on the market.
The main lter has an integrated particle lter
(HEPA) and gas- and dust lter for best function
and easylter exchange. The pre-lter protects
the mainlter and is changed separately for longer
lter lifetime.
Filtronic AB is striving to create a better workbench environment by developing and producing particle and gas lter
systems of very high quality. The lter systems are easy to use and install, have a low noise level and a guaranteed
function. Read more about us and our products at www.ltronic.se.
Max. media temperature 50°C (122°F)
FiLTroniC AB
Box 2284, SE-531 02 Lidköping, Sweden
Tel: +46 510 208 10, Fax: +46 510 201 40
E-mail: ofce@ltronic.se www.ltronic.se
For better workbench environment!