SMP260 Digital Encoder & Transcoder Quick Installation Guide V1.
SMP260 Quick Installation Guide V1.10-W Preface About This Document This document provides introductions and guidelines to users about how to install and operate this equipment quickly. Disclaimer Wellav Technologies Ltd. assumes no responsibility for errors or omissions that may appear in this publication. It reserves the right to change this publication at any time without notice.
SMP260 Quick Installation Guide V1.10-W Remarks. Additional information to the text, in order to emphasize something. Revision History The revision history lists the modification history. The newest one contains all the modifications of the past revision. V1.00: First revision. (Date: Nov 26th, 2012) V1.10: Optimize the document structure. (Date: Nov 22nd, 2012) Wellav Technologies Ltd.
SMP260 Quick Installation Guide V1.10-W Contents 1. Safety ............................................................................................................................ 5 2. Check Package and Accessories .................................................................................. 6 3. Physical specifications ................................................................................................... 7 4. 5. 6. 3.1 Physical Specifications ..............................
SMP260 Quick Installation Guide V1.10-W 1. Safety z To avoid electric-shock hazards, do not open the receiver; refer service to qualified personnel only. z Do not expose the device in the sunlight, and keep it away from the heat source. z Do not block ventilation holes of the device so that air can circulate freely. z Switch the device off whenever it remains out of service for an extended period.
SMP260 Quick Installation Guide V1.10-W 2.
SMP260 Quick Installation Guide V1.10-W 3. Physical specifications 3.1 Physical Specifications Items Power Index 90V-260VAC, 50/60Hz Power Consumption 125W Size 1RU Dimension 482mm x44mm x 393mm Net Weight 5Kg Gross Weight 7.5Kg 3.
SMP260 Quick Installation Guide V1.10-W 4. Front Panel and Rear Panel 4.1 Front Panel SMP260-Encoder 1 2 3 4 5 6 7 8 9 10 11 12 Pic-4-1 Item No. Functionality 1 Power status indicator 2 ASI/IP input status indicator 3 Input status indicator 4 Alarm status indicator 5 ASI/IP output status indicator 6 Encoding status indicator 7 LED displaying screen 8 KEY PADS, including Up/Down/Left/Right arrow keys 9 Menu. To enter the menu and the quit function of the sub menus. 10 OK.
SMP260 Quick Installation Guide V1.10-W 4 ASI/IP output status indicator 5 Transcoding status indicator 6 LED displaying screen 7 KEY PADS, including Up/Down/Left/Right arrow keys 8 Menu. To enter the menu and the quit function of the sub menus. 9 OK. To confirm the operation in the setup. 10 ESC. The quit function of the menu. 11 Reset. To reboot the equipment. 4.2 Rear Panel SMP260 Encoder-SDI/CVBS 1 2 1 3 4 5 6 7 Pic-4-3 Item No.
SMP260 Quick Installation Guide 3 ASI OUT 4 MANAGEMENT: 100BaseTX, RJ45 5 TS/IP IN/OUT 6 POWER V1.10-W SMP260 Transcoder 1 2 3 4 5 6 Pic-4-5 Item No. Functionality 1 Equipped transcoding modules 2 ASI IN 3 ASI OUT 4 MANAGEMENT: 100BaseTX, RJ45 5 TS/IP IN/OUT 6 POWER Wellav Technologies Ltd.
SMP260 Quick Installation Guide V1.10-W 5. Installation Instruction 5.1 Mounting unit to a 19” rack When selecting the installation site, try to comply with the following: z Protective Ground - The protective ground lead of the building's electrical installation should comply with national and local requirements. z Environmental Condition - The installation site should be dry, clean, and ventilated. Do not use this equipment where it could be at risk of contact with water.
SMP260 Quick Installation Guide V1.10-W PIC-5-2 5.2 Wiring Connection 1 Before setting up the connection, please turn off the equipment and all other connected external devices. The equipment and all connected external devices are required grounded. Turn on the devices only after the wiring connection is completed. Otherwise the device may be damaged.
SMP260 Quick Installation Guide z Set up cable connection for output signal: either through ASI (area 3) or TS/IP (area 4) z Set up connection for network management control: shown in area 5. V1.10-W In order to ensure a smooth communication between the management PC and the equipment, please separate the connection of management port and TS/IP output port to different switch. The switch with management port connected should be without large data processing.
SMP260 Quick Installation Guide V1.10-W 6. Operation Instructions 6.1 Powering Up & Initializations Before powering-up the device, make sure that all cabling is correctly connected (refer to chapter 5.2). The device is correctly connected to the power inlet and grounded. Switch on the equipment through the back power switch, the unit is powered up and start the initialization.
SMP260 Quick Installation Guide z V1.10-W Exit Menu/Back to parent Menu Upon completion of configuration settings, press “MENU” button until you go back to the Parent Menu. z z You can also go back to Parent Menu directly by pressing “ESC” button once. Enter Sub-Menu Press MENU button to enter main menu. Select a sub-menu by pressing arrow UP and arrow DOWN button. Press OK button on the selected sub-menu. To change parameter Step 1: Enter main menu by pressing MENU button.
SMP260 Quick Installation Guide V1.10-W quick installation, NMS operation is highly recommended. In this installation guide, operation instruction is based on NMS style. For front panel operation instruction, please refer to product user manual. z z Install the NMS Tool Unpack the accessory CD, and put it on a PC CD/DVD driver; Copy the NMS program on the CD to any folder of the management PC; Use mouse to double click the NMS icon and run the NMS program.
SMP260 Quick Installation Guide V1.10-W z Main Interface Introduction After successful log on, the following screen will display: Pic-6-2 The interface can be divided into four areas according to its functionality. (1) Toolbar. It includes shortcut to change password and save setting etc. (2) Equipment list. If more than a piece of equipment is connected to the NMS, the equipment will be listed in this area by its IP address. (3) Parameter setting and configuration area.
SMP260 Quick Installation Guide V1.10-W 6.3.1 Check “Status” tab “Status” tab: by selecting this item, the NMS displays the current system operation data status of the equipment.
SMP260 Quick Installation Guide V1.10-W Pic-6-3 Following are the key parameters: Parameters Description Channel Select a channel to configure its parameters. Video Source To select the correct video source for the input. Audio Source To select the correct audio source for the input. Encode Mode Select CBR or VBR for the encoding mode. Video Max Encode Rate To set the Max encode rate for VBR mode. The range of max encode rate is 2000 ~ 15000 Kbps. To set the Min encode rate for VBR mode.
SMP260 Quick Installation Guide Audio Encode Rate Encode Rate Audio Mode V1.10-W To choose the encoding bitrate for the audio. The total encode rate of video and audio contents. Calculated automatically by the software. To select the audio mode To select correct frame rate according to the input Frame Rate source. The frame rate should be the same as that of input source.
SMP260 Quick Installation Guide V1.10-W Pic-6-4 Parameters Description Type Set each ASI port to be Input or Output. Packet Size Set 188 or 204 packet size for outputs. Mode Set ASI port into CBR or VBR for output. Constant Rate(Mbit) Set constant bit rate for ASI output. Max Rate(Mbit) Set max bit rate for ASI output. Min Rate(Mbit) Set min bit rate for ASI output.
SMP260 Quick Installation Guide V1.10-W should be in the same IP section with IP address of the equipment. Subnet Mask Set Subnet Mark of the IP module Gateway Set Gateway of the IP module MAC Address MAC address of the IP module Speed Mode IGMP Version Set RJ45 connection speed mode. The speed mode support 100Mbit and 1000Mbit. Set IGMP Version for multicast. The IGMP version setting should match the IGMP version of the switch in the network.
SMP260 Quick Installation Guide Parameters ChannelSelect V1.10-W Description In this ‘ChannelSelect’, user can select a channel to configure its parameters. On: enable the IP receiving function. Enable Off: disable the IP receiving function. Note: this parameter setting applies to all channels.
SMP260 Quick Installation Guide V1.10-W Pic-3.3-40 Parameters Description In this ‘ChannelSelect’, user can select a channel to ChannelSelect configure its transmitting parameters. On: enable the IP transmission function. Enable Off: disable the IP transmission function. Note: this parameter setting applies to all channels.
SMP260 Quick Installation Guide ConstantRate(Mbit) Set constant bitrate for output MaxRate(Mbit) Set max bitrate for output MainRate(Mbit) Set min bitrate for output V1.10-W 6.3.3 Program IN/OUT configuration in “Program Info” tab Operation Buttons a) Transfer button: to transfer the selected stream/PID from the input program window to the output program window. b) Set button: to apply the changes to the NMS. The setting will lose if the NMS is close or the equipment is powered off.
SMP260 Quick Installation Guide V1.10-W Pic-3.3-20 ①Input Program Configuration: The “Input Program Configuration” is on the left side of the “Program Info” window. It displays all the inserted modules information and the received input streams. SD‐Encoder CVBS Slot1 SD‐Encoder CVBS Slot2 SD‐Encoder CVBS Slot3 ASI Interface Pic-3.3-21 Wellav Technologies Ltd.
SMP260 Quick Installation Guide a) V1.10-W Board1~4 represents the corresponding slots of the equipment. If the slot is inserted with a card module, the corresponding Board No. will be displayed on the “Input Program Configuration” window, and the name of the inserted module will be displayed after the Board No. b) For empty slot, no Board No. will be displayed. c) Port No.: represents each physical port of the inserted module.
SMP260 Quick Installation Guide Scan completes V1.10-W and receives data Pic-3.3-22 Output program configuration Select the port which you want to transmit the output stream. Pic-3.3-41 Select a TS stream, click the mouse right button. In the pop-up menu, select “Add TS”. Wellav Technologies Ltd.
SMP260 Quick Installation Guide V1.10-W Pic-3.3-42 Input the “Original Network ID” and “TS ID” for the channel, and click the “Add” button. Pic-3.3-43 The input “Original Network ID” and “TS ID” will be assigned to the selected output TS (channel). Pic-3.3-44 To change the “Original Network ID” and “TS ID”, use the left mouse button to click the TS (channel) name when it is being selected. Then the TS (channel) name will be in editable status. Pic-3.
SMP260 Quick Installation Guide V1.10-W button on the TS, and select “Delete”. Pic-3.3-46 Select TS which is going to be transmitted on the left hand side “Input Program Info” window, and select the port, TS (channel) which are going to carry the transmission on the right hand side “Output Program Info” window. Pic-3.3-47 Click the button to set transfer of the selected TS from the “Input Program Info” to the “Output Program Info”. Wellav Technologies Ltd.
SMP260 Quick Installation Guide V1.10-W Pic-3.3-48 Follow above operation steps, user can set the selected input stream to be transmitted at any assigned output TS (channel). Wellav Technologies Ltd.
SMP260 Quick Installation Guide V1.10-W 7. FAQ Problem Possible Reasons What to do Check whether the power cord is plugged into the power socket. The LCD display on the front No power. panel does not light up. Parameters are not Check the properly configured. configuration Check the source and other factors that affect the signal reception.
SMP260 Quick Installation Guide V1.10-W 8.