Technical data

44
Heating Tips
Heavy Duty -
Oxy-LP
Actual Size Tip
Medium pressure oxy-propane or propane based
heating tips provide high heating performance with
low cost fuel gases including natural gas and propane based gases.
USED IN:
Torch Handles
- WH200 & SW1B.
NOTE: ST635 requires 3/8” I.D. (10mm) hose and HB1522B-510 propane cylinder regulator.
CAUTION: Heating tips must be used in conjunction with high flow flashback arrestors.
It may be necessary to increase outlet pressures to compensate for flow restrictions
that may be created by flashback arrestors.
MT615
ST625
ST628
ST615
Stock No. of Uses Pressures (PSIG) Consumption (SCFH) Average **Fuel Overall Head
No. Flames Oxygen Fuel Gas Oxygen Fuel Gas BTU Cylinders Required Length PN
MT615 Fluted Propane 20-60 10-25 225-535 70-160 286,350 1-2 19” 1495
Natural Gas 15-50 10-25 175-450 96-267 181,500 (483mm)
Medium Duty / Oxy-Propane, Natural Gas
Multi-flame heating tip used with propane, propane based fuels
and natural gas.
USED IN:
Torch Handles
- WH100, MW5A & CW5A.
**Note: Continuous use with 100 lb. propane tanks @ 70˚ F.
Actual Size Tips
Tips
Stock No. of Uses Pressures (PSIG) Consumption (SCFH) Average ** Fuel Cylinders Overall Head
No. Flames Oxygen Fuel Gas Oxygen Fuel Gas BTU Required Length PN
ST615 Fluted Propane 23-65 10-28 225-535 70-160 244,000 1-2 15-3/4” 1495
Natural Gas 18-55 10-28 175-450 96-267 155,145 N/A (400mm)
Propylene 20-60 10-28 235-430 100-160 280,000
ST625 Propane 50-110 17-28 480-1000 140-280 455,000 2-3 31-1/2” 1504
Natural Gas 43-80 18-28 390-785 200-450 313,950 N/A (800mm)
ST635 Propane 70-115 18-40 670-1580 185-480 614,195 2-4 31-1/2” 1499
(800mm)
**Note: Continuous use with 100 lb. propane tanks @ 70˚ F.
ST628 Any Length Pipe May Be Used
Head and Mixer Assemblies ONLY
PIPE
Custom built heating tips for
maximum versatility in heating
operations. Make any length
heating tip. All that is required
is to add the desired length
of pipe (with 1/4” NPT pipe
thread on either end) and
attach to the heating
assemblies. Pipe is not supplied.
Head and Mixer Assemblies
USED IN:
Torch Handles
- WH200 & SW1B
Stock No. of Uses Pressures (PSIG) Consumption (SCFH) Average **Fuel Head
No. Flames Oxygen Fuel Gas Oxygen Fuel Gas BTU Cylinders PN
Required
ST628*
Fluted Propane 50-110 17-28 480-1000 140-280 455,000 2-3 1504
Natural Gas 43-80 18-28 390-785 200-450 313,950
*Head and Mixer Assembly Only
**Note: Continuous use with 100 lb. propane tanks @ 70˚ F.
ST625
ST615