Network Configuration
The DVR uses 4 sets of TCP/IP ports for network communication. See the following
table for details.
Function Default Value
Data Transmission 7050-7055*
Events 7056
DDNS 10000
WWW (Web Port) 80
* Only first port needs to
be specified and the SAgent will use the subsequent 5
ports automatically.
If default values are used, port 7050 is used for login, ports 7051 and 7052 are
u
sed for VOD (Video On Demand), ports 7053 and 7054 are used for live video,
and port 7055 for time information.
To configure network settings:
1. In the SAgent main user interface, click the Setup Options button.
2. The Options window opens with the Ne
twork tab active. Fill out the
information and adjust settings as necessary. See “Options Field Definitions:
Network Tab” on page 3-3 for details.
This check box is
displayed when you
click the Advanced
button.
3. Click OK to save the changes and close the window.