Specifications
7–4
Cordless Systems Manual
600 mAh
7,200
12 Hours
8 Hours
1200 mAh
14,000
20 Hours
4 Hours
Parameter Specification
NiCad (Nickel Cadmium)
Capacity
Number of Scans (between charges)
Expected Hours of Operation ]
Charge Time
NiMH (Nickel Metal Hydride)
Capacity
Number of Scans (between charges)
Expected Hours of Operation ]
Charge Time for 800 mA/h
Battery Charging (Input) Voltage
The battery packs are designed with an integrated charging circuitry to allow
them to be plugged directly into any common 120 Volt outlet [. Battery packs
have an LED indicator to signal charging and fully-charged conditions. In order
to break in the new battery, we suggest that you fully charge and discharge the
packs approximately two to four times so they can reach their full-rated capacity.
[ North America
only
. All other countries require a Charge Strip (available as
an accessory).
] Usage Model = one (1) scan every five (5) seconds.
NiMH Battery Pack: Recommended Storage [[
–20° C to 55° C (–4° F to 131° F)
–20° C to 45° C (–4° F to 113° F)
–20° C to 35° C ( –4° F to 95° F)
+10° C to 25° C (50° F to 77° F)
Storage Time Storage Temperature
Up to a month
Up to 3 months
Up to a year
Longer than a year
Battery Specifications
NiCad Battery Pack: Recommended Storage [[
–20° C to 45° C (–4° F to 113° F)
–20° C to 35° C ( –4° F to 95° F)
Storage Time Storage Temperature
Up to 6 months
Up to 2 years
[[ When storing battery packs for longer than 6 months, recharge at least once
a year (once every 6 months if possible) to prevent self–discharge from
causing a drop in battery performance or electrolyte leakage.
85 to 264 VAC @ 47 to 63 hz
600 mAh
7,200
12 Hours
4 Hours @ 60 hz
5 Hours @ 50 hz
1200 mAh
14,000
20 Hours
4 Hours
120 Volt/60 hz
120 Volt/60 hz
240 Volt