Specifications

3–17
Cordless Systems Manual
You are sending five digit data into the Auxiliary Port; however, your host system
can only accept data which has eight digits. You must add three zeroes to the
beginning of the Aux Port data.
Aux Data Formatter Example
H Scan the
Enter Aux Data Format
bar code (page 3–15).
H Scan the
99
bar codes for Universal Terminal Type.
Refer to the Aux Format Editor Commands Chart on page 3–16 to format the
following example. The programming bar codes on page 3–15, and the
alphanumeric bar codes on the inside back cover are used to program the data
formatter.
H Scan the
72
bar codes, the Hex value for the Auxiliary Port.
H Scan the
0005
bar codes for the data length.
H Scan the
F4
(send XX character NN times command) bar codes, scan
30
bar codes (the Hex value for a zero), scan
03
bar codes (send three times).
H Scan the
Save
bar code to end Aux Format Editor selection.
The following are the Aux Editor Command Sequences:
Received Must send
12345 00012345
H Scan the
F1
and
00
bar codes to send all data followed by a NUL (NUL= 00
in Hex value).