Installation and operating instructions
Technische. Änderungen vorbehalten! 7 Copyright HRB3662
Installation of the electrics
The electrics may only be installed by a qualified electrician in accordance with the VDE and EVU guidelines.
Information on assembly of the sauna furnace and the control device can be found in the enclosed assembly
instructions.
On exposure to the mains voltage, there is a risk of SERIOUS INJURY OR DEATH!
The system must be disconnected from the mains on all poles during all installation and repair work (switch
off the fuse or mains switch).
Sauna lights
Allow lighting to cool before replacing the bulbs.
Only use commercially available bulbs that have a maximum wattage of 40 W and that are permitted for an
ambient temperature of 125°C. Energy-saving bulbs with electronic components are not suitable!
The lamp must not be installed over the sauna stove and also not within 50 cm horizontally from the sauna
stove.
If the outer flexible cable of the lamp set is damaged, it may only be replaced by a special cable or by a
cable that can only be obtained from the manufacturer or its service representative.
Only cables rated for a continuous temperature of at least 170°C may be used.
Technical data:
Mains voltage: 230 V~, 50 Hz
Socket: E27
Max. power: ceiling installation: max. 40 W
Ambient temperature: 125°C
IP54 protection rating
Connection:
Acc. to European Directive 2002/96/EC regarding electrical and electronic
used devices and its implementation in national law, used electrical tools
must be collected separately and recycled in an environmentally sound
manner.
Assembly recommendations
Please drill pilot holes for all screw connections to avoid
damaging the wood. The following symbol in the
instructions will indicate when this is necessary: