Note:
The control equipment may be destroyed even if it is
incorrectly connected only once. The warranty will be
voided if the electrical connection is not correct.
Instructions for the electrician
DINVDE0100andAccidentPreventionRegulationBGVA2
mustbeobservedforconnectingthestoveandallelectrical
systems.Anexternalall-poledisconnectingdevicewithfull
isolationaccordingtoovervoltagecategoryIIImustbeinstalled.
Important:
Mains connection leads must be exible cables with
polychlorophenesheaths.Noconnectionleadsaresupplied
withthestove.Allthecablesinstalledinsidethecabinmust
besuitableforanambienttemperatureofatleast170°C.heat
resistantsiliconcablesmustbeused.Theminimumcross-
sectionoftheconnectioncableandtheminimumsizeofthe
saunacabinareshowninthetable(Table1page8).Makethe
electricalconnectionasshownintheconnectiondiagram.
Aconnectiondiagramisadditionallyaxedtotheinsideofthe
ductcover.Fitthecoveraftermakingtheelectricalconnection.
Pleasenotethatlivecablesmustnotberoutedvisiblyonthe
internalwallsofthecabinforsafetyreasons.Inprefabricated
saunacabins thewallelement with the air supplyopening
generallyhasemptycableconduitsoraductforroutingthecable.
Ifyourcabindoesnothaveanycableroutingpreparations,
we recommend that you install a connection socket (not
supplied)totheoutsideofthecabin.Drillaholeinthecabin
wallnearthecableinfeedfromthestoveandtheconnection
socket. Thread the cable through the hole to the external
connection socket. All cables must be protected from
damage. This can be achieved using installation ducting/
pipingorusingwoodencovers.
Connection diagram
Testing the insulation resistance
The resistance values between the various conductor
terminalsandthehousing(protectiveearth)canbemeasured
using an insulation resistance measuring unit. The total
insulation resistancebetween the conductor terminals and
housing(protectiveearth)mustdenitelybegreaterthan1
MOhm.Regulation3oftheDGUV(GermanSocialAccident
Insurance)Resistancevalueofindividualheatingcoils15-
44Ohm(3.6kw-9.0KW)
Position the sauna stones on the stone grid
Saunastonesareanaturalproduct.Werecommendthatyou
cleanthestoneswithcleanwaterbeforeplacingthemonthe
stove.Donotusestonesunlesstheyaredesignedforuse
inasauna. Use amaximumof10 kgofstones.Important.
Positionthestoneslooselyandremoveanystonesthatare
toosmall.Ifthestonesarepackedtootightlytheywillaect
theaircirculationandwillresultinthesaunastoveandcabin
wallsoverheatingandarerisk.Donotusethestovewithout
stones.Onlyusestonesthataremarkedassaunastonesin
shops.Warrantyclaimswillnotbeacceptedifstonesother
thanthosedesignedforuseinsaunasareusedorforclaims
resultingfromllingofthestonechambersincorrectly.Turn
thestonesatleastonceperyear,removeanystonesthatare
toosmallandremoveallstonedustandstonesplinters.We
recommendthatyoureplacethestoneseverytwoyears.
Important:
Ifyoucoverthestoveandllthestonecontainerincorrectly
theunitmaycauseare.Donotusethestovewithoutsauna
stones.