Table 3 Combined space heating/water
heating (see Notes)
Table 4 Dedicated water-heating, using circulator
supplied with boiler (see Notes)
Boiler PLUS
Model
1st Hour
rating, GPH
Boiler
piping
Head losses, Feet w.c. DHW
Pump
115°F 140°F GPM
Rec.
size
Boiler Heater Piping TOTAL
Ultra-
80
40 160 124
6.6 1" 5.8 1.0 2.4 9.2 007
60 168 132
80 176 140
100 190 155
110 210 175
119 230 190
Ultra-
105
40 203 141
6.4 1" 5.9 1.0 2.3 9.3 007
60 211 162
80 219 170
100 230 185
110 250 205
119 270 225
Ultra-
155
40 238 153 8.7 1" 5.7 1.0 3 .9 10.6
0010
60 294 190 9.6 1¼" 7.1 1.0 2.3 10.5
80 302 230
10.8 1¼" 9.0 1.0 2.8 12.8 0012
100 315 245
110 335 265
119 355 285
Ultra-
230
40 248 160
12.0 1¼" 8.2 1.0 3.4 12.6 0012
60 330 196
80 411 305
13.5 1¼" 10.0 1.0 4.2 15.2 0014
100 440 335
110 460 355
119 480 375
Ultra-
310
40 254 164 15.0 1¼" 6.0 1.0 5.1 12.1 0012
60 351 208 18.6 1½" 8.5 1.0 3.3 12.8 0011
80 579 373
22.0 1½" 11.2 1.0 4.5 16.6 0013
100 440 335
110 460 355
119 480 375
1. First hour ratings in Tables 3 and 4 are based
on:
115°F or 140°F domestic outlet water supply
temperature from water heater.
50°F domestic water inlet temperature.
190°F boiler water temperature leaving
Gas boiler.
Circulator and pipe sizes as given in the
Tables.
2. If the net Btu/hr rating of the boiler is close to
the space heating load (for combined systems)
or if there is an unusually large demand for
domestic water increased boiler capacity
may be required.
Boiler PLUS
Model
1st Hour
rating, GPH
Boiler
piping
Head losses, Feet w.c. Circ.
115°F 140°F GPM
Rec.
size
Boiler Heater Piping TOTAL
Ultra-
80
40 160 124
6.6 1" 5.8 1.0 2.4 9.2 007
60 168 132
80 176 140
100 190 155
110 210 175
119 230 190
Ultra-
105
40 203 141
6.4 1" 5.9 1.0 2.3 9.2 007
60 211 162
80 219 170
100 230 185
110 250 205
119 270 225
Ultra-
155
40 250 160
12.1 1¼” 11.4 1.0 4.5 16.9 0014
60 295 2 20
80 305 2 30
100 315 245
110 335 265
119 355 285
Ultra-
230
40 240 1 70
13.5 1¼” 10.0 1.0 5.2 16.2 0014
60 335 2 20
80 430 3 25
100 440 335
110 460 355
119 480 375
Ultra-
310
40 240 1 70
18.3 1½” 8.3 1.0 4.2 13.5 0014
60 335 2 20
80 580 4 10
100 590 435
110 610 465
119 630 485
Notes Tables 3 and 4
Figure 16 Pump curves for Taco circulators
Gas
The following ratings are for Ultra Gas boilers only, with supply water temperature at 190°F.