Replacement Parts List

Table Of Contents
GAS
266 Discontinued Service Parts
EG - Series 2 Through 4
Water Trim Parts
Fig.
No.
Part No. Description Mfr. Mfr.’s Part No.
Temperature Controls For All EG Water Boilers Without Tankless Heaters
(Except EG-75 Standing Pilot)
1 510-312-209
High Limit Temperature Control SPST (Automatic Recycle,
140-240°F 10°F Fixed Subtractive Differential With ¾" N.P.T.
Well)
Honeywell L4080B1311
Temperature Controls For EG-75 Standing Pilot
2 510-312-150
Combination Operating Limit (140-240°F Range) and Fixed
High Limit (240°F Temperature Control, Auto Recycle, DPST,
With ¾" Well. Fixed High Limit, Furnished With Wire Leads For
Connection To Thermocouple Spade Terminal Block)
Carlin EZ Temp 90224
Temperature Controls For All EG Water Boilers With Tankless Heaters
N/S 510-312-249
Combination High Limit / Low Limit / Circulator Control with
Transformer
(High Limit: SPST Automatic Recycle, 140-240°F Range, 10°F
Subtractive Differential)
(Low Limit / Circulator Control: SPDT, Automatic Recycle,
100-200°F Range, 10-35°F Adjustable Differential)
Honeywell L8124E-1065
1
3
5
4
2