Install Instructions
Part number 550-100-131/0715
– 72 –
™
GAS-FIRED WATER BOILER — Boiler Manual
&IGURE Evergreen control settings available in BASIC MODE (see Advanced Manual for ADVANCED MODE settings)
Available control settings and system presets
&IGURE System types available in BASIC MODE (each option shown with factory settings)
!VAILABLESETTINGSFROM#/.42!#4/2-%.5
"OILER3ETTINGS-ENU 0RIORITYMENU !SSIGN)NPUTSMENU
s Boiler Model s Inputs Assigned (non-selectable)
)NPUT44
s Control Type s System Type s Priority 1, 2 or 3
s High Altitude s Target Mod Sensor (non-selectable) s Source (TT1 or 0-10v)
s LP Gas s Target Adjust (non-selectable) s AUX PUMP/OUTPUT
s ODT Sensor Exempt s Supply Max s Off
s Manual Reset High Limit Temp s Supply Min (not available for DHW) *
s WWSD Temp s OD Reset Max (or Volts for Max) *
)NPUT44AND)NPUT44
s Adjust Outdoor s OD Reset Min (or Volts for Min) * s Priority 1, 2 or 3
s Circulator Exercising s Boost Time * s AUX PUMP/OUTPUT
s Freeze Protect Circs s Off
s Reset Factory Default
0RIORITYMENU
s Inputs Assigned (non-selectable)
$IAGNOSTICSMENU
0RIORITYMENU
s System Type s See Figure 77, page 78 for details.
s Inputs Assigned (non-selectable) s Target Mod Sensor (non-selectable)
s System Type s Target Adjust (non-selectable)
-AINTENANCE)NFOMENU
s Target Mod Sensor (non-selectable) s Supply Max s See Figure 82, page 83 for details.
s Target Adjust (non-selectable) s Supply Min (not available for DHW) *
s Supply Max s OD Reset Max (or Volts for Max) *
3ET$ATEAND4IMEMENU
s Supply Min (not available for DHW) * s OD Reset Min (or Volts for Min) * s See Figure 82, page 83 for details.
s OD Reset Max (or Volts for Max) * s Boost Time *
s OD Reset Min (or Volts for Min) * * These items only appear in the menus if Target Adjust is active.
s Boost Time *
3YSTEM4YPE
8-Character
Abbreviation
3-Character
Abbreviation
Supply Max
°F
OD Reset
Min °F
Supply
Min °F
OD Reset
Max °F
Run
Boiler Pump
Run AUX
PUMP/
OUTPUT
Fan-coil FAN-COIL
FCL 180 0 140 70 YES YES
Finned Tube Baseboard FIN BASE
FTB 180 0 130 70 YES YES
Cast Iron Baseboard IRONBASE
CIB 180 0 120 70 YES YES
Cast Iron Radiators RADIATOR
CIR 180 0 120 70 YES YES
Radiant - slab on grade RAD SLAB
RSG 120 0 80 70 YES YES
Radiant - thin slab RAD SLAB
RTS 140 0 80 70 YES YES
Radiant - below floor
(staple up)
RADFLOOR
RSU 160 0 90 70 YES YES
Radiant - above floor
(sleeper system)
RADFLOOR
RAF 140 0 90 70 YES YES
Domestic Hot Water DOMESTIC
DHW 180 N/A N/A N/A NO NO
Custom (user defined)
XXXXXXXX
(user input)
first three of
user input
180 0 70 70 YES YES