User Guide

Part number 550-100-400/0717
102
U-Control operation and setup — advanced (continued)
-ENUS .EXTSCREEN .EXTSCREEN .EXTSCREEN .EXTSCREEN
Follow information at the bottom of each screen to navigate to next/previous screen or enter/save data
BOILER SETTINGS BOILER MODEL ##### 80
105
155
230
299
310
399
#AREFULLYVERIFYTHATTHEBOILERMODEL
NUMBERONTHEDISPLAYNOWAGREES
WITHTHEBOILERRATINGPLATE3ETTING
THESE INCORRECTLYCOULD RESULT IN
SEVERE PERSONAL INJURY DEATHOR
SUBSTANTIALPROPERTYDAMAGE
HIGH ALTITUDE ### NO
YES
HIGH TEMP LIMIT ###
WWSD SETTING ###
°F
ADJUST OUTDOOR ###
°F
###
###
ADD’L HEAT DEMAND
TYPE: ###########
OFF
TYPE 1 — ULTRA = PRIMARY HEAT SOURCE
TYPE 2 — ULTRA = BACKUP HEAT SOURCE
TYPE 3 — ULTRA = LEAD (0–10V OUTPUT)
TYPE 4 — ULTRA = SHADOW (0–10V INPUT)
ADD’L HEAT DEMAND
TIME: ### MINUTES
##
MINUTES
SYSTEM SETTINGS BOILER PRIORITY 1 SYSTEM TYPE: ### OFF
FAN COIL
FINNED TUBE BASEBOARD
CAST IRON BASEBOARD
CAST IRON RADIATOR
RADIANT — SLAB ON GRADE
RADIANT — THIN SLAB
RADIANT — ABOVE FLOOR
CUSTOM
DHW – DIRECT
DHW – SYSTEM
TEMPERATURES MAX SUPPLY: ### °F
MIN SUPPLY: ### °F
MAX OUTDOOR: ### °F
MIN OUTDOOR: ### °F
MODULATE ON DIFF: ### °F
MODULATE OFF DIFF:### °F
MIN SUPPLY, MAX
OUTDOOR AND MIN
OUTDOOR are not
shown for DHW types
TIMES MAX ON TIME: ### MIN
MIN ON TIME: ### MIN
BOOST INTERVAL: ### MIN
PRE PUMP TIME: ### SEC
POST PUMP TIME: ### SEC
not on Priority 3
not on Priority 1
CIRCULATORS: # # # CIRCULATOR 1: ###
CIRCULATOR 2: ###
CIRCULATOR 3: ###
ON/OFF
ON/OFF
ON/OFF
MAXIMUM RATE: ___%
MINIMUM RATE: ___%
### %
### %
BOILER PRIORITY 2
BOILER PRIORITY 3
SAME MENUS AS FOR PRIORITY 1
SAME MENUS AS FOR PRIORITY 1
CIRCULATOR EXERCISING CIRCULATOR 1: ###
CIRCULATOR 2: ###
CIRCULATOR 3: ###
ON/OFF
ON/OFF
ON/OFF
FREEZE PROTECT CIRCS CIRCULATOR 1: ###
CIRCULATOR 2: ###
CIRCULATOR 3: ###
ON/OFF
ON/OFF
ON/OFF
MAINTENANCE INFO NAME
PHONE
MODEL
CP#
INSTALLED
LAST DATE
NEXT DATE
INTERVAL SETTINGS
RESET REMINDER
################
###-###-####
ULTRA #####
##########
MM/DD/YY
MM/DD/YY
DD/MM/YY
## MONTHS
PRESS ENTER TO RESET
&IGURE U-Control menus (press and hold the UP and DOWN arrow keys for 5 seconds to enter contractor menus)
®
SERIES 4 GAS-FIRED WATER BOILER — Boiler Manual