Install Instructions

CG i
GAS-FIRED
wATER
BOILER-
sERIEs
a-
Boiler
Manual
7b
Start-up
-
operate
boiler
r-1&:-:-:-
W
:-:
A
-::
R
.,-
N
"'
IN
c-
G
:'\1
DO
NOT
proa!ed with boiler
operation
mliess boiler
and
system have been tilled with water
and
all instructions
. .
and
procedures
of
previous manual sections have been completed. Failure
to
do
so
could
result
in
severe personal
injury, death
or
substantial property damage. Before starting the boiler,
do
the following:
Read manual
Section
9
and
the
OperaUng
Instruction
procedure applicable for
the
gas valve supplied
on
th
e boiler (Section
9c
).
Verify the boiler
and
system are full
of
water
.
Verify the
Start-up
preparation
procedures
of
Section
7 have been completed.
Adjust
boiler
control
settings
BOILER OPERATING TEMPERATURE
With power
turned
on,
control
module
receives a signal from
the
temperature sensor
and
displays boiler temperature.
The
control
knob
labeled
BOILER
TEMP
is u
sed
to
adjust
the
operating temperature setpoint,
turning
clockwi
se
to
increase
temperature
sett
ing
and
counterclockwise
to
decrease. When
the
knob
is
turned
to
adjust temperature the display will brighten
to
indicate adjustment mode. After temperature is
set
to
desired
value, displ
ay
will
dim
after approximately 5 seconds
to
indicate
measurement mode.
ADJUST
BOILER
OPERATING
TEMPERATURE
TO
DESIRED
SETPO
I
NT.
BOILER ECONOMY SETTING
Th comply with
Department
of
Energy regulations, the
contro
l
module circulates available
hot
water before
turn
ing on the boiler
to
attempt
to
satisfy a call for heat. While attempting
to
satisfy
th
e
heat
demand,
the control module also monitors
th
e boiler
temperature changes via
the
temperature sen
sor
and
determines
whether
or
not
the
available h
ot
water will satisfy the
demand,
adjusting the time delay
to
turn
on
th
e boiler until
it
determines
th
at
additional heat will
be
needed. The knob label
ed
ECONOMY
ADJUST
provides
an
adjustment between maximize
(JV!AX)
and
minimize
(M
IN)
the
delay.
The
max:immn
(JV!AX)
adjustment
position
sho
u
ld
be
used
to
ma,imize
energy savings. Turning
th
e
knob
counterclockwise decreases
th
e
de
l
ay
time
and
sh
ould
only
be
used in the event
that
th
e heated space becomes uncomfortable.
ADJUST
ECONOMY
TO
DESIRED
PO
SmON
(MAX
IS
THE
PREFERRED
SETTING)
.
IMPORTANT
In
accordana! with Section 325 (f) (3)
of
the Energy
Policy
and
Conservation Act,
this
boiler is equipped with a feature
that
saves energy
by
reducing
the
boiler water temperature
as
th
e heating l
oad
decreases. This feature is
equipped
with
an
override which is provided primarily
to
permit
the
use
of
an
external energy management system
that
serves the same
function.
34
THIS OVERRIDE MUST
NOT
BE
USED UNLESS AT LEAST
ONE
OF
THE
FOLLOWING
CONDIT
IONS IS TRUE:
An
external energy manage
ment
system
is
installed
that
reduces
the
boiler water temperature
as
the heating load
decreases.
This boiler
is
part
of
a
modular
or
multiple boiler system
having a total
input
of
300,000 BTU/hr
or
greater.
This boiler
is equipped with a tankless coil.
I&
WARNINGI
I&
WARNING!
I&
WARNING!
If
you
discover
evidence
of
any
gas
leak,
shut
down
the
boiler
at
once. Find
the
l
eak
so
urce
with
bubble
test
and
repair
immedia
tel
y.
Do
not
start
boiler
again until
corrected
Failure
to
comply
could
result
in
severe
personal
injury
,
death
or
s
ub
stantial
property
damage.
Eliminate
all
system
leaks.
Continua
l
fresh makeup water will reduce boiler life.
Minerals
can build
up
in sections, reducing
heat
tran
sfe
r,
overheating cast iron,
and
causing section failure.
Glycol
or
antifreeze
leaks
around
the
boiler may result
in
tire, causing severe per-
sona
l injury, death
or
substantial property
damage.
Do
not
us
e
petroleum-based
cleaning
or
sealing
compounds
in boiler system.
Severe damage
to
boiler will occur, result-
ing
in substantial property damage.
Part Number 550-142-780/0712