User Guide
GOLD CGt Gas-Fired Water Boiler User’s Information Manual
Part Number 550-110-291/0709
5
Maintain boiler using schedule below
Tankless water heater
If boiler is used to supply domestic hot water, limit
control should be set to supply adequate hot water.
Weil-McLain tankless heaters are rated at 200°F boiler
water temperature. To get rated output, set low limit
at 200°F. Limit can be adjusted to meet system hot
water requirements. Lowering the setting will cause a
slight variation in water temperature but will decrease
burner on-off cycling. High limit should be set at least
20° above low limit.
Service technician
(covered in Boiler Manual — for use only by a
qualified service technician)
Owner maintenance
(see following pages for instructions)
ANNNUAL START-UP
Inspect:
• Reported problems
• Boiler area
• Air openings
• Flue gas vent system
• Pilot and main burner flames
• Water piping
• Boiler heating surfaces
• Burners, base and inlet air box
Service:
• Oiled-bearing circulators
Start-up:
• Perform start-up per manual
Check/test:
• Gas piping
• Cold fill and operating pressures
• Air vents and air elimination
• Limit controls and cutoffs
• Expansion tank
• Boiler relief valve
Review:
• Review with owner
Daily
• Check boiler area
• Check air openings
• Check boiler pressure/
temperature gauge
Monthly
• Check boiler interior piping
• Check venting system
• Check air vents
• Check boiler relief valve
• Check automatic air vents (if
used)
Periodically • Test low water cutoff (if used)
Every 6 months • Operate relief valve
End of season • Shut down procedure