Datasheet

Application
The moving-coil panel meters PQ 48/72/96/144 K (K series) housed in
moulded thermoplastic cases are suitable for the measurement of DC
currents and voltages.
The instruments are suitable to be mounted in switchboards, control pan-
els, machine tool consoles and mosaic panels. The bezel, the glass win-
dow and the dial can be easily exchanged on -site.
Movements
Self-shielding moving -coil movements with core-type magnet and
pivot suspension. Spring loaded jewel bearings for vibration and shock
resistance.
Mechanical Data
case details moulded square case suitable to be mounted
in control / switchgear panels, machine tool
consoles or mosaic panels, stackable
material of case polycarbonate thermoplastics,
flame retardant with UL rating of 94 V – 0
material of window glass '
colour of bezel black (similar to RAL 9005) '
position of use vertical ±5° '
panel fixing screw clamps
or spring clamps (except PQ 144 K)
mounting stackable next to each other
panel thickness
40 mm
terminals
voltmeters and hexagon studs, M4 screws and
ammeters
4 A wire clamps E3
ammeters
60 A threaded studs M6 with nuts
ammeters 100 A threaded studs M8 with nuts
dimensions (in mm) PQ 48 K PQ 72 K PQ 96 K PQ 144 K
bezel V 48 V 72 V 96 V 144
case V 42.5 V 66 V 90 V 136
depth 53 53 53 53
panel cutout V 45
+0.6
V 68
+0.7
V 92
+0.8
V 138
+1
weight approx. 0.11 kg 0.15 kg 0.2 kg 0.25 kg
Electrical Data
measuring unit DC voltage or current
overload capacity acc. to DIN EN 60 051 - 1
continuously 1.2 times rated voltage / current
5 s max. 2 times rated voltage,
10 times rated current
measurement category CAT III
operating voltage refer to Measuring Ranges
pollution level 2
enclosure code IP 52 case front side
IP 00 for terminals without protection against
accidental contact
IP 20 for terminals protected against
accidental contact '
' also refer to ”Options”
Measuring Ranges
For mains use
DC current voltage drop approx. DC voltage >5V
PQ 48K PQ 72/96/144K sensitivity
1
)'
100 mA 270 mV 400 mV 6 V 1 kW/V
1 mA 30 mV 40 mV 10 V 1 kW/V
1.5 mA 90 mV 200 mV 15 V 1 kW/V
2.5 mA 90 mV 200 mV 25 V 1 kW/V
4 mA 90 mV 200 mV 40 V 1 kW/V
5 mA 100 mV 200 mV 60 V 1 kW/V
6 mA 100 mV 200 mV 100 V 1 kW/V
10 mA 100 mV 200 mV 150 V 1 kW/V
15 mA 15 mV 15 mV 250 V 1 kW/V
20 mA 60 mV 60 mV 400 V
2
)
3
)1 kW/V
25 mA 60 mV 60 mV 500 V
2
)
3
)1 kW/V
40 mA 60 mV 60 mV 600 V
2
)
3
)1 kW/V
60 mA 60 mV 60 mV
1 A 60 mV 60 mV
1.5 A 60 mV 60 mV
2.5 A 60 mV 60 mV
4 A 60 mV 60 mV
6 A 60 mV 60 mV
10 A 60 mV 60 mV
15 A 60 mV 60 mV
25 A 60 mV 60 mV
40 A
2
) 60 mV
60 A
2
) 60 mV
100 A
2
) 60 mV
for use with external shunt
60 mV current consumption 15 mA approximately,
150 mV a total lead resistance of 0.035 W is considered in the
calibration of the indicator for interconnecting leads 1 m, 2x 1 mm
2
Not for mains use
DC voltage 5V sensitivity
1
)'
60 mV; 100 mV; 150 mV; 250 mV; 400 mV; 600 mV 1 kW/V
1 V; 1.5 V; 2.5 V; 4 V; 5 V 1 kW/V
for use on transducer (”live zero”)
4 ... 20 mA mechanically suppressed zero, without zero
adjustment, voltage drop approx. 60 mV
0/4 ... 20 mA
2
)electrically suppressed zero, with zero adjustment,
voltage drop approx. 900 mV
Operating Voltages
measuring ranges operating voltage '
DC current PQ 48 K PQ 72 K PQ 96 K PQ 144 K
100 mA
1; 1.5; 2.5; 4; 5; 6; 10;
15; 20; 25; 40; 60 mA 150 V 150 V 150 V 150 V
1; 1.5; 2.5; 4; 6; 10;
15; 25 A 150 V 150 V 150 V 150 V
40; 60; 100 A
2
) 150 V 150 V 150 V
DC voltage PQ 48 K PQ 72 K PQ 96 K PQ 144 K
60; 100; 150; 250;
400; 600 mV 150 V 150 V 150 V 150 V
1; 1.5; 2.5; 4; 6; 10;
15; 25; 40; 60; 100 V 150 V 150 V 150 V 150 V
150 V 150 V 150 V 150 V 150 V
250 V 300 V 300 V 300 V 600 V
400; 500; 600 V
2
)
3
) 600 V 600 V
1
) the resistance values are limited to a tolerance of ±20%
2
) not for PQ 48 K
3
) not for PQ 72 K