Datasheet
Connections
DC voltage
17 18
L+
L-
DC current
17 18
L+
L-
Dimensions
c
b
a
dimensions (in mm) PQ 48 K PQ 72 K PQ 96 K PQ 144 K
a 48 72 96 144
b 42.5 66 90 136
c 53 53 53 53
ordering example
PQ 72 K, measuring range 0 ... 20 mA, window non - glaring glass,
dial with linear scale division 0 ... 100°C, red mark at 37°C,
no logo
Ordering Information
type
PQ moving–coil panel meter
front dimensions
48 K 48 mm x 48 mm
72 K 72 mm x 72 mm
96 K 96 mm x 96 mm
144 K 144 mm x 144 mm
measuring ranges refer to preceding table
”live zero” 4 ... 20 mA mechan. suppressed zero
1
)
0/4 ... 20 mA electric. suppressed zero
3
)
window glass
1
)
non- glaring glass
colour of bezel black (similar to RAL 9005)
1
)
gray (similar to RAL 7037)
position of use vertical
1
)
on request 15 ... 165°
2
)
panel fixing screw clamps
1
)
spring clamps (except PQ 144 K)
marine application none
1
)
non- certified
with approbation by
”Germanischer Lloyd” (except PQ 48 K)
terminal protection none
1
)
full- sized rear cover
protective sleeves
index marking none
1
)
pointer red, front adjustable
zero position left hand zero position
1
)
centre or off- set zero position
2
)
increased sensitivity 1 kW/V
1
)
4 kW/V for voltmeters 1 ... 600 V
10 kW/V for voltmeters 1.5 ... 150 V
adjustment of ±20%
1
)
resistance to ±1% at 23°C
dial scale division & measuring range alike
1
)
no dial
non- calibrated, with dial symbols
blank dial
scale division and figuring 0 ... 100%
linear scale division
2
)
additional lettering on request
2
)
additional figuring on request
2
)
coloured mark red, green or blue
2
)
coloured sector red, green or blue
2
)
dial illumination none
1
)
refer to ”Options”
logo WEIGEL
1
)
none
OEM logo
2
)
1
) Standard
2
) Please clearly add the desired specifications.
3
) not for PQ 48 K
Weigel Meßgeräte GmbH
Postfach 720 154 S 90241 Nürnberg S Phone: 0911 / 4 2347- 0
Erlenstraße 14 S 90441 Nürnberg S Fax: 0911/ 4 23 47- 39
Sales: Phone: 0911 / 4 2347- 94
Internet: http://www.weigel–messgeraete.de
e–mail: vertrieb@weigel–messgeraete.de
– specifications subject to change without notice; date of issue 08/15 –