User manual

WI-MOD-9-E Wireless Ethernet User Manual
WI-MOD-9-E Manual V1.9 Page 26
My Right Boot 2.1
Copyright 1999-2004 Cybertec Pty Ltd, All rights reserved.
This software is provided by Cybertec ``as is'' and with NO WARRANTY.
http://www.cybertec.com.au/
ROM : 256KB @ 0xffe00000
RAM : 8192KB @ 0x00000000 (141KB / 0x0002366c)
ROM Configuration table ... PASSED.
RAM address pattern check . PASSED.
RAM address bus check ..... PASSED.
Product : E900P R2.3F
Variant : default-variant
Serial No. : 09040569 - 012345678910
Release : epm_mrb_elpro_E900P_1.5
Released date : 11 August 2005
Released host : Anxosity
Build date : Thu Aug 11 12:01:05 2005
Build host : Anxosity
Boot Flags : no RAM test, no ROM test, bus timer on, wdog on
static IP, auto-boot, net-boot, reset on
local file, no binary load
Boot delay : 0
Boot Filename : /memory/0xffe40000,0x60000
Boot Address : 192.168.123.113
Boot Netmask : 255.255.255.0
Boot Gateway : 192.168.123.113
Boot Host : 192.168.123.1
Boot Mac 0 : 00:12:af:00:00:10
Boot Mac 1 : 00:12:af:00:00:10
RTE data store .... no error
Setting bus timer (on) and watchdog (on) ... PASSED
Recovery Configuration :
ip address : 192.168.0.110
net mask : 255.255.255.0
gateway : 192.168.0.1
host : 192.168.0.1
eip: mount point /memory
fec0: connected at 100M Full Duplex.
fec0: local ip = 192.168.0.110, server ip = 192.168.0.1
Press ENTER to abort automatic booting ... 5
e) Check values for Boot Address, Boot Netmask, and Boot Gateway. These values should be
set to reflect those of the PC you are using to configure the unit. If these are correct skip to
step (h). You may check settings again with the rct command. For further help, type the help
command.
f) Set Boot Netmask to the same settings as the computer you have the Ethernet cable
connected to. This may be performed with the command: bnm <Type the netmask>
g) Set Boot Gateway to the same settings as the computer you have the Ethernet cable
connected to. This may be performed with the command: bgw <Type the gateway IP
address>
h) Choose an IP address for the WI-MOD-9-E being upgraded. This IP address must be on the
same network as the computer you have connected the Ethernet cable to. This may be
performed with the command: bip <Type the IP address>
i) Switch dip-switch on WI-MOD-9-E to RUN position.