Datasheet
Type Qty. Order no.
ZQV 16-10 10 7920080000
For standard For roof-type
terminal terminal
ZDU 10… ZDU 10 S
ZPE 10… ZNT 10 S
ZDU 16 ZDU 16 S
ZPE 16 ZPE 16 S
ZNT 16 S
ZQV 16-10
Reducing cross-connection
Type Qty. Order no.
ZQV 4/2 60 1608950000
ZQV 4/3 60 1608960000
ZQV 4/4 60 1608970000
ZQV 4/5 20 1608980000
ZQV 4/6 20 1608990000
ZQV 4/7 20 1609000000
ZQV 4/8 20 1609010000
ZQV 4/9 20 1609020000
ZQV 4/10 20 1609030000
For standard For roof-type
terminal terminal
ZDU 4… ZDU 4-2…
ZDK 4/S… ZDU 4 S
ZNT 4 S
ZEI 16 ZEI 16-2/1 AN
ZQV 4
Terminals, Z-Series
C.106
C
Accessories – Electrical distribution
Cross-connections
Type Qty. Order no.
ZQV 35-16 10 7920120000
For standard For roof-type
terminal terminal
ZDU 16 ZDU 16 S
ZPE 16 ZPE 16 S
ZDU 35
ZPE 35
ZQV 35-16
Reducing cross-connection
Type Qty. Order no.
ZQV 35-10 10 7920100000
For standard For roof-type
terminal terminal
ZDU 10… ZDU 10 S
ZPE 10… ZPE 10 S
ZDU 35
ZPE 35
ZQV 35-10
Reducing cross-connection
Type Qty. Order no.
ZQV 2.5/2 60 1608860000
ZQV 2.5/3 60 1608870000
ZQV 2.5/4 60 1608880000
ZQV 2.5/5 20 1608890000
ZQV 2.5/6 20 1608900000
ZQV 2.5/7 20 1608910000
ZQV 2.5/8 20 1608920000
ZQV 2.5/9 20 1608930000
ZQV 2.5/10 20 1608940000
ZQV 2.5/50 10 1697540000
For standard For roof-type
terminal terminal
ZDU 2.5… ZDU 2.5-2…
ZDK 2.5/1.5… ZDK 2.5-2
ZTR 2.5… ZTR 2.5-2…
ZDTR 2.5 ZDLD 2.5-2…
ZSI 2.5… ZDKPE 2.5-2
ZRV 1.5… ZDU 2.5 S
ZIA 1.5…. ZNT 2.5 S
ZEI 16 ZEI 16-2/1 AN
ZQV 2.5
Type Qty. Order no.
ZQV 1.5/2 60 1776120000
ZQV 1.5/3 60 1776130000
ZQV 1.5/4 60 1776140000
ZQV 1.5/5 60 1776150000
ZQV 1.5/10 20 1776200000
For standard For roof-type
terminal terminal
ZDU 1.5….
ZDK 1.5….
ZEI 6
ZQV 1.5
Tailor-made cross-connections
ZQV 2.5/50 is a cross-connection
which can be used for connecting up
to 20 individual terminals easily and
quickly. The fitter simply cuts off the
required number of poles from the 50
pole cross-connection comb. With
this system, cross-connections with
the correct number of poles are al-
ways available, and only a minimum
of storage space is required. The
large number of poles in the 50-pole
comb means that unused residual
quantities are virtually avoided. The
ends of the continuous cross-con-
nection are bare.
In the interests of stability, 2-pole
cross-connections are not allowed.
An end cover plate must always be
fitted to neighbouring ZQVs with bare
cut edges. In ZDU 2.5 and WDU 2.5
it is sufficient to fit the ZQV in the off-
set position. The rated voltage is 400
V. In general, ZQV 2.5/50 can be
used for up to 20 poles.
Colour range
Different colours for marking the vari-
ous cross-sections are available on
request (e.g. differing circuits when
using 2 cross-connection channels).
Articles with coloured order number are kept permanently in stock at the central warehouse in Germany.
Delivery times see page X.2