Data Sheet
Data sheet
OMNIMATE Signal - series BL/SL 3.50
BLZF 3.50/14/180LR SN OR BX
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 16
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Creation date May 27, 2019 3:07:37 PM CEST
Catalogue status 23.05.2019 / We reserve the right to make technical changes. 3
Clampable conductor
Cross-section for conductor connection Type
fine-wired
nominal
0.5 mm²
AEH Stripping length nominal
12 mm
Stripping length nominal
10 mm
Cross-section for conductor connection Type
fine-wired
nominal
0.75 mm²
AEH Stripping length nominal
12 mm
Stripping length nominal
10 mm
Cross-section for conductor connection Type
fine-wired
nominal
1 mm²
AEH Stripping length nominal
12 mm
Stripping length nominal
10 mm
Cross-section for conductor connection Type
fine-wired
nominal
1.5 mm²
AEH Stripping length nominal
10 mm
Reference text The outside diameter of the plastic collar should not be larger than the pitch (P).
Max. clamping range 1.5 mm²
Rated data acc. to IEC
tested acc. to standard
IEC 60664-1, IEC 61984
Rated current, min. no. of poles
(Tu=20°C) 14.5 A
Rated current, max. no. of poles
(Tu=20°C) 10 A
Rated current, min. no. of poles
(Tu=40°C) 12 A
Rated current, max. no. of poles
(Tu=40°C) 8 A
Rated voltage for surge voltage class /
pollution degree II/2 320 V
Rated voltage for surge voltage class /
pollution degree III/2 160 V
Rated voltage for surge voltage class /
pollution degree III/3 160 V
Rated impulse voltage for surge voltage
class/ pollution degree II/2 2.5 kV
Rated impulse voltage for surge voltage
class/ pollution degree III/2 2.5 kV
Rated impulse voltage for surge voltage
class/ contamination degree III/3 2.5 kV
Short-time withstand current resistance
3 x 1s with 100 A
Rated data acc. to CSA
Rated voltage (Use group B / CSA) 300 V
Rated voltage (Use group D / CSA) 300 V
Rated current (Use group B / CSA) 10 A
Rated current (Use group D / CSA) 10 A
Wire cross-section, AWG, min. AWG 26
Wire cross-section, AWG, max. AWG 14
Rated data acc. to UL 1059
Rated voltage (Use group B / UL 1059) 300 V
Rated voltage (Use group D / UL 1059) 300 V
Rated current (Use group B / UL 1059) 10 A
Rated current (Use group D / UL 1059) 10 A
Wire cross-section, AWG, min. AWG 26
Wire cross-section, AWG, max. AWG 14
Packing
Packaging Box
VPE length 80 mm
VPE width 115 mm
VPE height 165 mm
Classifications
ETIM 4.0 EC002637
ETIM 5.0 EC002637
ETIM 6.0 EC002638
eClass 6.2 27-26-07-04
eClass 7.1 27-44-04-02
eClass 8.1 27-44-04-02
eClass 9.0 27-44-03-09
eClass 9.1 27-44-03-09






