Datasheet
Data sheet
ACT20M
ACT20M-CI-2CO-S
Weidmüller Interface GmbH & Co. KG
Klingenbergstraße 26
D-32758 Detmold
Germany
Fon: +49 5231 14-0
Fax: +49 5231 14-292083
www.weidmueller.com
Technical data
Creation date January 24, 2020 3:24:39 PM CET
Catalogue status 13.01.2020 / We reserve the right to make technical changes. 2
Dimensions and weights
Width 6.1 mm
Width (inches) 0.24 inch
Height 112.5 mm
Height (inches) 4.429 inch
Depth 114.3 mm
Depth (inches)
4.5 inch
Net weight 83.6 g
Temperatures
Humidity 95 %, no condensation
Operating temperature, max. 70 °C
Operating temperature, min. -25 °C
Storage temperature, max. 85 °C
Storage temperature, min. -40 °C
Operating temperature -25 °C...70 °C
Ambient temperature -25 °C...+70 °C
Storage temperature -40 °C...85 °C
Probability of failure
MTBF 219 Years
Environmental Product Compliance
REACH SVHC Lead 7439-92-1
Rated data UL
UL certificate E337701.pdf
Input
Number of inputs
1
Sensor Current source, Sensor
with own supply, 4-wire
sensor
Input current 0...20 mA, 4…20mA
Voltage drop, current input
< 1.5 V
Input resistance, current 70 Ω
Output
Number of outputs 2
Output current 0...20 mA, 4...20 mA
Cut-off frequency (-3 dB) 100 Hz
load impedance voltage
≥ 10 kΩ
load impedance current < 300 Ω, per channel, @
max 23mA
General data
Accuracy < 0.05 % of measuring
range
Configuration
none
Galvanic isolation 3-way isolator
Power consumption, max. 0.75 W
Power consumption, typ. 0.53 W
Rail TS 35
Step response time ≤ 7 ms
Temperature coefficient
≤ 0.01 % / °C
Voltage supply 24 V DC ± 30 %
Insulation coordination
EMC standards IEC 61326-1, NE 21
Galvanic isolation 3-way isolator
Insulation voltage 2.5 kV
eff
/1 min.
Pollution severity
2
Rated voltage 300 V
eff
Surge voltage category
II