Approval/Certificate/Document of Conformity

Job Id: 262.1-026382-1
Certificate No: TAA00001G5
Form code: TA 251
Revision: 2016-12
www.dnvgl.com
Page 2 of 2
Product description
Input signal
(PRO DC/DC)
uni-/bipolar 20 mV up to 200 V
uni-/bipolar 0,1 mA up to 100 mA
(PRO RTD)
PT 100 2,3,4 wire / R / Potentiometer
(PRO THERMO)
Thermoelement type K,J, T, E, N, R, S, B
Output signal
0 ... +/- 10V, 0.. +/- 20 mA
Power supply
20 ... 230 V AC/DC (Thermo / RTD 20...27 V
DC)
Gain error
< 0.1 % of final value
Temperature coefficient
< 60 ppm/K of final value
Rated isolation voltage Ui
300 V (PRO DC/DC 600 V )
for overvoltage category III and pollution degree
2
Degree of protection
IP 20
Connection
Screw-type WAS5...; Tension clamp WAZ5...
Detail according catalogue
5618420000/04/2001/VSD/Me
Application/Limitation
Operating instruction of the manufacturer to be observed
Ex-certification is not covered by this certificate. Application in hazardous area to be approved in each
case according to the Rules and Ex-Certification/ Special Condition for Safe Use listed in valid Ex-
certificate issued by a notified/recognized Certification Body
Tests carried out
Applicable tests according to Class Guideline DNVGL-CG-0339, Nov 2016
Marking of product
The products to be marked with:
- manufacturer name
- model name
- serial number
- power supply ratings
Periodical assessment
The scope of the periodical assessment is to verify that the conditions stipulated for the type are
complied with, and that no alterations are made to the product design or choice of systems, software
versions, components and/or materials.
The main elements of the assessment are:
Ensure that type approved documentation is available
Inspection of factory samples, selected at random from the production line (where practicable)
Review of production and inspection routines, including test records from product sample tests and
control routines
Ensuring that systems, software versions, components and/or materials used comply with type
approved documents and/or referenced system, software, component and material specifications
Review of possible changes in design of systems, software versions, components, materials and/or
performance, and make sure that such changes do not affect the type approval given
Ensuring traceability between manufacturer’s product type marking and the type approval certificate
Periodical assessment is to be performed at least every second year and at renewal of this certificate.
END OF CERTIFICATE