User Documentation

332661740000/01/06-2020
Specications
Specications
Features
Self-calibration
Illuminated color TFT display and touch screen interface
User congurable menu and options
Auto-detection of type of SPD component connected
Measurement programs for MOVs, GDTs and ABDs
Test GDTs and MOVs up to 1500 V DC
Display of successive measurements using LOG mode
Internal intelligent battery charger
Remote rmware update capability
General specications
Specication Characteristics
Size 220 mm (W) x 205 mm (H) x 82 mm (D)
Weight (with batteries) 1.1 kg
Battery size, quantity Type AA, 5 ea.
Battery type NiMH (supplied)
Battery life (typical) 200 hours idling
Operating temperature -10 ºC...+50 ºC
Storage temperature -10 ºC...+60 ºC indenitely (to -40 ºC for 100 hrs)
Relative humidity 80 % @ 10 ºC...35 ºC
70 % @ 35 ºC...40 ºC
Operating altitude 0...2000 m
Vibration Class 3 per Mil-Prf-28800F
Enclosure sealing IP 20
Enclosure material ABS (UL 94 HB)
Pollution degree 2
Measurement accuracy
Specication Characteristics
MOV / ABD constant currents options 0.1 mA, 0.5 mA, 1.0 mA
GDT voltage ramp rate options 100 V/s, 1000 V/s
Max. Test voltage 1500 V DC
MOV measurement accuracy* 1.5 % +/- 2 digit counts
GDT measurement accuracy* 1 kV/s: 3.5 % ±2 digit counts
100 V/s: 1.6 % ±2 digit counts
* The accuracy specication is dened as ±(% reading + digit counts) at 25 ºC ±5 ºC, < 80 % RH.